TD200-2003-3PH, VFD, 3HP, 240V 3PH IN, 240V 3PH OUT
TD200-2003-3PH, VFD, 3HP, 240V 3PH IN, 240V 3PH OUT
FMX TD200 Series Variable Frequency AC Drive (VFD), 3HP, 240V 3PH Input, 240V 3PH Output, 10.5 FLA, Frame 2, IP20
Quantity Pricing
Specifications
FMX TD200 Series Variable Frequency AC Drive (VFD), 3HP, 240V 3PH Input, 240V 3PH Output, 10.5 FLA, Frame 2, IP20
- Auto-tuning Sensorless Vector Control with V/HZ mode
- Pulse Width modulation (PWM utilizing IGBT technology)
- Built-in PID control
- 150% rated current for 1 minute, 200% instantaneous
- 2 Analog Inputs: 0-10VDC and 4-20mA signals
- Digital Inputs: 5 NO/NC selectable
- 1 Analog Output (0-10VDC)
- 1 Multi-function Digital Relay Output
- Built-in dynamic braking transistor (480V Models)
- Electronic overload protection and stall prevention
- Ground fault and short circuit protection
- Built-in RS485
- 2 year warranty
General Specifications
| Rated Input Power | 240V Class – 200 to 240V, +10% / -15% |
| Output Voltage Range | 240V: 0–240V, 3-Phase |
| Rated Output Frequency | 0–599Hz |
| Output Frequency Accuracy | 0.01Hz |
| Control Mode | Sensorless Vector, V/Hz |
| Carrier Frequency | 1 to 16kHz |
| Frequency Control Range | 0.01–599.00Hz |
| Speed Control Accuracy | V/Hz: +/- 2% Sensorless Vector: +/- 0.5% |
| Overload Capacity | 150% Rated Output Current for 60 sec. |
| Frequency Setting Signal | 0-10VDC, 4-20mA |
| Accel/Decel Time | 0–3600 sec. (Independent Accel/Decel Times) |
| Number of V/F Patterns | 6 Preset V/F Patterns, 1 Custom V/F Pattern |
| Braking Torque | Approximately 20% |
| Protective Functions | Stall Prevention, Instantaneous Overcurrent (200%), Motor Overload Protection, Overvoltage, Undervoltage, Momentary Power Loss, Overheat Protection, Ground Fault |
Environmental Conditions
| Location | Indoor (IP20) |
| Ambient Temperature | 14 to 122°F (-10 to 50°C) |
| Storage Temperature | -4 to 158°F (-15 to 70°C) |
| Altitude | <1000m |
| Humidity | <95% RH (Non-condensing) |
| Vibration | 9.8m/s2 (1.0G) |
| Agency Approvals | UL/cUL File# E503131, RoHS, CE 61800-3, IEC 60018-2-78 |
Dimensions
| Frame Size | 2 |
| Dimensions | 5.16"H x 4.65"W x 5.91"D (131mm x 118mm x 150mm) |
| Recommended Air Circulation Space | 4.8" Top and Bottom = 9.6"H 2" Each Side = 4" W 2" to the Depth = 2" D |
Resources
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-AAA-001 FAQ's for AC Drives (VFD) | Frequently Asked Questions for Variable Frequency Drives (VFD) | |
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. | |
| AN-GEN-006 AC Drive Single Phase Input Derating | How to calculate the derated output current for a three-phase AC drive | |
| AN-TD2-001 TD200 PID Quick Start | How to setup PID control for TD200 series AC drives. | |
| AN-TD2-002 FM50 Series to TD200 Series Model Number and Parameter Cross Reference | Cross reference charts for FM50 series to TD200 series AC drives. | |
| AN-TD2-003 TD200 Series Frequency Source Selection | How to set the Frequency Source for TD200 series AC drives. | |
| AN-TD2-004 TD200 Series Run Command Source Selection | How to set the Run Command Source for TD200 series AC drives | |
| AN-TD2-005 TD200 Series Emergency Stop | How to setup a digital input on the TD200 series AC drive as an Emergency Stop | |
| AN-TD2-006 TD200 Series Forward and Reverse Jog | How to setup the TD200 to use Jog controls | |
| AN-TD2-007 TD200 Series Analog Output Setup | How to setup the Analog Output on TD200 series AC drives | |
| AN-TD2-008 TD200 Series Motor Rotation Direction Check | How to check the Motor Rotation Direction for Accuracy | |
| AN-TD2-009 Wiring Devices Using External Power Supply | How to wire externally powered devices to the TD200 input terminals. | |
| AN-TD2-010 Using a Panel Meter with TD200 | How to use a panel meter and potentiometer to provide external speed display and control with the TD200 | |
| AN-TD2-011 Connecting the Tough Drive to TD-Link Software | Establishing a connection between the Tough Drive and TD-Link software... | |
| AN-TD2-015 TD200 Drive Error Codes | A list of error codes used in TD200 series AC drives ... | |
| AN-TD2-016 TD Series AC Drives | Tough Drive STP0 Display on Start... |