TD200-2002-3PH, VFD, 2HP, 240V 3PH IN, 240V 3PH OUT

FMX TD200 Series Variable Frequency AC Drive (VFD), 2HP, 240V 3PH Input, 240V 3PH Output, 7.5 FLA, Frame 2, IP20
Item: TD200-2002-3PH
(0) No Reviews yet
$169.00

Quantity Pricing

1+
$169.00
3+
$165.62
6+
$160.55
10+
$156.33
SKU: TD200-2002-3PH
$169.00
Orders up to 7PM ET Ship same day!
Weight: 3.52 lbs.
Made in: China

Related Videos

Specifications

FMX TD200 Series Variable Frequency AC Drive (VFD), 2HP, 240V 3PH Input, 240V 3PH Output, 7.5 FLA, Frame 2, IP20
  • Auto-tuning Sensorless Vector Control with V/HZ mode
  • Pulse Width modulation (PWM utilizing IGBT technology)
  • Built-in PID control
  • 150% rated current for 1 minute, 200% instantaneous
  • 2 Analog Inputs: 0-10VDC and 4-20mA signals
  • Digital Inputs: 5 NO/NC selectable
  • 1 Analog Output (0-10VDC)
  • 1 Multi-function Digital Relay Output
  • Built-in dynamic braking transistor (480V Models)
  • Electronic overload protection and stall prevention
  • Ground fault and short circuit protection
  • Built-in RS485
  • 2 year warranty

General Specifications

Rated Input Power240V Class – 200 to 240V, +10% / -15%
Output Voltage Range240V: 0–240V, 3-Phase
Rated Output Frequency0–599Hz
Output Frequency Accuracy0.01Hz
Control ModeSensorless Vector, V/Hz
Carrier Frequency1 to 16kHz
Frequency Control Range0.01–599.00Hz
Speed Control AccuracyV/Hz: +/- 2%
Sensorless Vector: +/- 0.5%
Overload Capacity150% Rated Output Current for 60 sec.
Frequency Setting Signal0-10VDC, 4-20mA
Accel/Decel Time0–3600 sec. (Independent Accel/Decel Times)
Number of V/F Patterns6 Preset V/F Patterns, 1 Custom V/F Pattern
Braking TorqueApproximately 20%
Protective FunctionsStall Prevention, Instantaneous Overcurrent (200%), Motor Overload Protection, Overvoltage, Undervoltage, Momentary Power Loss, Overheat Protection, Ground Fault

Environmental Conditions

LocationIndoor (IP20)
Ambient Temperature14 to 122°F (-10 to 50°C)
Storage Temperature-4 to 158°F (-15 to 70°C)
Altitude<1000m
Humidity<95% RH (Non-condensing)
Vibration9.8m/s2 (1.0G)
Agency ApprovalsUL/cUL File# E503131, RoHS, CE 61800-3, IEC 60018-2-78

Related Items

Knowledge base

TitleSummaryRelated Links
AN-GEN-004

Determining Motor Full Load Amps (FLA)

How to determine your motor’s FLA.
AN-TD2-001

TD200 PID Quick Start

How to setup PID control for TD200 series AC drives.
AN-TD2-002

FM50 Series to TD200 Series Model Number and Parameter Cross Reference

Cross reference charts for FM50 series to TD200 series AC drives.
AN-TD2-003

TD200 Series Frequency Source Selection

How to set the Frequency Source for TD200 series AC drives.
AN-TD2-004

TD200 Series Run Command Source Selection

How to set the Run Command Source for TD200 series AC drives
AN-TD2-005

TD200 Series Emergency Stop

How to setup a digital input on the TD200 series AC drive as an Emergency Stop
AN-TD2-006

TD200 Series Forward and Reverse Jog

How to setup the TD200 to use Jog controls
AN-TD2-007

TD200 Series Analog Output Setup

How to setup the Analog Output on TD200 series AC drives
AN-TD2-008

TD200 Series Motor Rotation Direction Check

How to check the Motor Rotation Direction for Accuracy
AN-TD2-009

Wiring Devices Using External Power Supply

How to wire externally powered devices to the TD200 input terminals.
AN-TD2-010

Using a Panel Meter with TD200

How to use a panel meter and potentiometer to provide external speed display and control with the TD200
AN-TD2-011

Connecting the Tough Drive to TD-Link Software

Establishing a connection between the Tough Drive and TD-Link software...

Ratings & Reviews

No reviews available

Be the first to Write a Review

Related Videos