SSW900E0604T5E3B, Soft Starter, 3 PH, 604A
SSW900E0604T5E3B, Soft Starter, 3 PH, 604A
WEG Electric SSW900 Soft Starter, 3 PH, 604A (250HP/230V, 500HP/460V, 650HP/575V), 22.6"Hx15.4"Wx10.2"D
Item: SSW900E0604T5E3B
Weight: 83.7 lbs.
Made in: Brazil
See Price in Cart
$9,628.35
SKU:SSW900E0604T5E3B
Specifications
WEG Electric SSW900 Soft Starter, 3 PH, 604A (250HP/230V, 500HP/460V, 650HP/575V), 22.6"Hx15.4"Wx10.2"D
- Universal voltage (220 to 575 VAC)
- Built-in bypass contactor
- Bluetooth Connectivity
- Removable HMI keypad LCD display
- Kick-Start function for high inertia loads
- Intelligent pumping system control
- Electronic motor protection
- Ambient temperature up to 55°C (131°F)
UL HP Ratings
| 220 / 230VAC 3-Phase | 250HP |
| 440 / 460VAC 3-Phase | 500HP |
| 575VAC 3-Phase | 650HP |
General Specifications
| Power Source Voltage | 220 to 575VAC |
| Power Source Frequency | 50 to 60Hz (±10%) or 45 to 66Hz |
| Control Voltage | 110 to 240VAC (-15% to +10%) 94 to 264VAC |
| Nominal Current | 604 |
| Dimensions | 22.6" H x 15.4" W x 10.2" D |
| Enclosure | Injected Plastic: IP00 |
| Control | Control Method: Voltage Variation over the load (three phase induction) Types of Control: Voltage Ramp, Current Limitation, Current Ramp, Pump Control, Torque Control, DOL SCR |
| Starting Cycle | Normal: 300% (3 x Inom.) during 30s, 10 starts per hour (every 6 minutes) |
| Inputs | Digital: 6 Isolated Programmable Inputs |
| Outputs | Relay: 2 Relays with Normally Open Contacts, 1 Relay with Normally Open or Normally Closed Contacts 240VAC, 1A, Programmable Function Analog: 1 0-10V or 0-20mA programmable analog output |
| Communication (Programming) | USB |
| Safety | Protections (standard): Programmable overvoltage, undervoltage, voltage imbalance, and phase sequence Programmable motor overload and underload Overcurrent, undercurrent, current imbalance, undertorque, overtorque, underpower, and overpower Input power short-circuit Bypass protections: Overcurrent, undercurrent, and bypass contactor failure Minimum time between starts Communication faults Fault auto-reset Overtemperature in Motor PTC (with Optional Accessory) |
| Standard Features | Torque Pulse at Start (Kick Start) DC Braking (with Contactor) Optimal Braking (without Contactor) Reverse Braking Emergency Start (Fire Mode) Fault Logging Parameter Copying via Keypad Real Time Clock SoftPLC (Ladder Programming) 2 Expansion Slots |
| Accessories and Options | CANopen and DeviceNet Module Modbus-RTU Module DeviceNet-Anybus Module Profibus Module Ethernet I/P Module Modbus-TCP Module Motor PTC Kit Profinet IO Module PT100 Temperature Module Ventilation Kits IP20 Kits External Current Transformers Remote Keypads |
| Finishing: Color | Lid: Gray Ultra Mat Cabinet: Blue Ultra Mat |
| Ambient Temperature | 14° to 131°F (-10° to 55°C) Standard Operation at Rated Current |
| Humidity | 0 to 90%, Non-Condensing |
| Altitude | 0 to 1000m (3,300 Feet) Standard Operation at Rated Current |
| Standards | UL 508 Standard - Industrial Control Equipment, File # E198842 |
Resources
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |