E13218EP3YAX315SMF3W, AC Mtr, TEFC, F3 , 3PH, 175 HP, 132 kW, 1500//1800 RPM, 315S/M NEMA, Ex nA, 380-415/660-690//440-460V, 50//60 Hz
E13218EP3YAX315SMF3W, AC Mtr, TEFC, F3 , 3PH, 175 HP, 132 kW, 1500//1800 RPM, 315S/M NEMA, Ex nA, 380-415/660-690//440-460V, 50//60 Hz
WEG AC Motor, Cast Iron Frame, TEFC, F3 Mount, 3 PH, 175 HP, 132 kW, 1500//1800 RPM, 315S/M NEMA Frame, Ex nA, 1.00 Service Factor, 380-415/660-690//440-460V, 50//60 Hz. **Must Ship LTL Truck Freight**
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Specifications
WEG AC Motor, Cast Iron Frame, TEFC, F3 Mount, 3 PH, 175 HP, 132 kW, 1500//1800 RPM, 315S/M NEMA Frame, Ex nA, 1.00 Service Factor, 380-415/660-690//440-460V, 50//60 Hz. **Must Ship LTL Truck Freight**
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- 1.25 service factor for 60 Hz operation (IE3)
- 1.15 service factor for 60 Hz operation (IE2)
- Optimized ventilation system for cooler operation and reduced noise levels
- Solid base for reduced vibration levels (Cast iron frames)
- Frames 225 and up can easily be F1 (B3L) converted by simply rotating the terminal box adapter or F3 by removing it
- Aluminum frames have removable feet for easy F1, F2 and F3 (B3L, B3R, B3T) conversion
- Terminal blocks
- Class F insulation (impregnation resin and magnet wire are class H)
- F2 mounted as standard (F1 convertible)
- Stainless steel nameplate - laser etched with high contrast background
- Regreasable ball bearings (Frames 160 and up)
- Gasketed conduit box
- Class I, Div, 2, Groups A, B, C & D - T3, Class II, Div 2, Groups F & G - T3C (Cast iron frames only)
- Suitable for WYE/Delta Start (W and Y voltage code motors)
Specifications
| Phase | Three Phase |
| Frame | 315S/M |
| Output | 132 kW |
| Poles | 04 |
| Frequency | 50 Hz |
| Rated speed | 1485 rpm |
| Slip | 1.00 % |
| Full Voltage - No Cables | 380-415/660//440-460 V |
| Rated Current | 240/138 A |
| LR Amperes | 1584/912 A |
| LRC | - |
| No Load Current | 71.2/41.0 A |
| Rated Torque | 626 ft.lb |
| Locked Rotor Torque | 190 % |
| Breakdown Torque | 220 % |
| Insulation Class | F |
| Service Factor | 1 |
| Moment of Inertia | 73.9 sq.ft.lb |
| Design | N |
| Locked Rotor Time | 39s (cold) 22s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-3 |
| Rotation Direction | Both |
| Noise Level | 71.0 dB(A) |
| Starting Method | Direct |
| Enclosure Material | Iron |
| Front Bearing Shielding | C3 |
| Front Bearing Size | 6319 |
| Front Bearing Type | Ball |
| Front Sealing Type | W Seal |
| Rear Bearing Shielding | C3 |
| Rear Bearing Size | 6316 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 10:1 |
| VFD Turndown CT | 2:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |