00336ET3WAL100L-W22, General Purpose, IEC Tru-Metric, TEFC, Footed, Aluminum, 3PH, 4HP, 3kW, 3600//3000RPM, 100L, 460//220-240/380-415
00336ET3WAL100L-W22, General Purpose, IEC Tru-Metric, TEFC, Footed, Aluminum, 3PH, 4HP, 3kW, 3600//3000RPM, 100L, 460//220-240/380-415
WEG NEMA Premium Efficiency, General Purpose, IEC Tru-Metric, TEFC, Foot Mount, Aluminum, 3Phase, 4HP, 3kW, 3600//3000RPM, 100L Frame, 460//220-240/380-415, 1 .25 Service Factor
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: 00336ET3WAL100L-W22
Weight: 65 lbs.
Made in: Brazil
$792.80
SKU:00336ET3WAL100L-W22
Specifications
WEG NEMA Premium Efficiency, General Purpose, IEC Tru-Metric, TEFC, Foot Mount, Aluminum, 3Phase, 4HP, 3kW, 3600//3000RPM, 100L Frame, 460//220-240/380-415, 1 .25 Service Factor
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Specifications
| Phase | Three Phase |
| Frame | 100L |
| Output | 4 HP |
| Poles | 02 |
| Frequency | 60 Hz |
| Rated speed | 3515 rpm |
| Slip | 2.36 % |
| Full Voltage - No Cables | 460//220-240/380-415 V |
| Rated Current | 5.01 A |
| LR Amperes | 46.6 A |
| LRC | - |
| No Load Current | 2.35 A |
| Rated Torque | 5.98 ft.lb |
| Locked Rotor Torque | 340 % |
| Breakdown Torque | 440 % |
| Insulation Class | F |
| Service Factor | 1.25 |
| Moment of Inertia | 0.1519 sq.ft.lb |
| Design | N |
| Locked Rotor Time | 32s (cold) 18s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-2 |
| Rotation Direction | Both |
| Noise Level | 71.0 dB(A) |
| Starting Method | Direct |
| Enclosure Material | Aluminum |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6206 |
| Front Bearing Type | Ball |
| Front Sealing Type | V Ring |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6205 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 12:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |