SSW900G1400T5E3B, Soft Starter, 3 PH, 1400A

SSW900G1400T5E3B, Soft Starter, 3 PH, 1400A

WEG Electric SSW900 Soft Starter, 3 PH, 1400A (550HP/230V, 1200HP/460V, 1400HP/575V), 36.0"Hx36.0"Wx12.4"D

Item: SSW900G1400T5E3B
(0) No Reviews yet
Weight: 236.3 lbs.
Made in: Brazil
Must Ship LTL Truck Freight
$32,521.45
Drop Ship Item
SKU:SSW900G1400T5E3B

Drop ship item: Typically ships within 1 business day.

Specifications

WEG Electric SSW900 Soft Starter, 3 PH, 1400A (550HP/230V, 1200HP/460V, 1400HP/575V), 36.0"Hx36.0"Wx12.4"D

  • Universal voltage (220 to 575 VAC)
  • Built-in bypass contactor
  • Bluetooth Connectivity
  • Removable HMI keypad LCD display
  • Kick-Start function for high inertia loads
  • Intelligent pumping system control
  • Electronic motor protection
  • Ambient temperature up to 55°C (131°F)

UL HP Ratings

220 / 230VAC 3-Phase 550HP
440 / 460VAC 3-Phase 1200HP
575VAC 3-Phase 1400HP

General Specifications

Power Source Voltage220 to 575VAC
Power Source Frequency50 to 60Hz (±10%) or 45 to 66Hz
Control Voltage110 to 240VAC (-15% to +10%) 94 to 264VAC
Nominal Current1400
Dimensions36.0" H x 36.0" W x 12.4" D
EnclosureInjected Plastic: IP00
ControlControl Method: Voltage Variation over the load (three phase induction)

Types of Control: Voltage Ramp, Current Limitation, Current Ramp, Pump Control, Torque Control, DOL SCR
Starting CycleNormal: 300% (3 x Inom.) during 30s, 10 starts per hour (every 6 minutes)
InputsDigital: 6 Isolated Programmable Inputs
OutputsRelay: 2 Relays with Normally Open Contacts, 1 Relay with Normally Open or Normally Closed Contacts
240VAC, 1A, Programmable Function
Analog: 1 0-10V or 0-20mA programmable analog output
Communication (Programming)USB
SafetyProtections (standard):
Programmable overvoltage, undervoltage, voltage imbalance, and phase sequence
Programmable motor overload and underload
Overcurrent, undercurrent, current imbalance, undertorque, overtorque, underpower, and overpower
Input power short-circuit
Bypass protections: Overcurrent, undercurrent, and bypass contactor failure
Minimum time between starts
Communication faults
Fault auto-reset
Overtemperature in Motor PTC (with Optional Accessory)
Standard FeaturesTorque Pulse at Start (Kick Start)
DC Braking (with Contactor)
Optimal Braking (without Contactor)
Reverse Braking
Emergency Start (Fire Mode)
Fault Logging
Parameter Copying via Keypad
Real Time Clock
SoftPLC (Ladder Programming)
2 Expansion Slots
Accessories and OptionsCANopen and DeviceNet Module
Modbus-RTU Module
DeviceNet-Anybus Module
Profibus Module
Ethernet I/P Module
Modbus-TCP Module
Motor PTC Kit
Profinet IO Module
PT100 Temperature Module
Ventilation Kits
IP20 Kits
External Current Transformers
Remote Keypads
Finishing: ColorLid: Gray Ultra Mat
Cabinet: Blue Ultra Mat
Ambient Temperature14° to 131°F (-10° to 55°C) Standard Operation at Rated Current
Humidity0 to 90%, Non-Condensing
Altitude0 to 1000m (3,300 Feet) Standard Operation at Rated Current
StandardsUL 508 Standard - Industrial Control Equipment, File # E198842

Related Items

Ratings & Reviews

No reviews available

Be the first to Write a Review

Ratings & Reviews

No reviews available

Be the first to Write a Review