IMO

IMC330-07S-10-AC240, Mini Contactor, 7A, 3 Pole, 1NO Aux, Coil: 208-240VAC

IMO

IMC330-07S-10-AC240, Mini Contactor, 7A, 3 Pole, 1NO Aux, Coil: 208-240VAC

FMX Mini Contactor, Non-reversing, 7A, 3 Pole, 600V, Screw Clamp Terminals, Aux: 1NO, Coil: 208-240VAC, 60Hz
Item: IMC330-07S-10-AC240
(0) No Reviews yet
Weight: 0.5 lbs.
Made in: Brazil
$14.50
In Stock Icon
In Stock
SKU:IMC330-07S-10-AC240

Orders up to 6PM ET Ship same day!    

Specifications

FMX Mini Contactor, Non-reversing, 7A, 3 Pole, 600V, Screw Clamp Terminals, Aux: 1NO, Coil: 208-240VAC, 60Hz
  • 1/3HP to 15HP
  • Surface or DIN-rail mountable
  • UL508 listed
  • 50/60Hz AC and DC coil versions available
  • Direct-mounting overloads
  • RoHS compliant
  • Auxiliary contacts standard (1 N.O.)
  • 1 year warranty

General Specifications

General Purpose Rating (A)18
Rated Operational Voltage (V)12 to 690
Rated Insulation Voltage (V)UL/CSA: 600, IEC/VDE 0660: 690
Rated Impulse Voltage IEC60947-1 (V)4000
Rated Operating Frequency (Hz)25 to 400
Degree of ProtectionIP20
Vibration Resistance (5 to 200Hz)
Contactor Open (g)2
Contactor Closed at Coil (g)4
Mechanical Endurance (Million ops)10
Electrical Endurance (Million ops) Shock Resistance (1/2 Sin Wave = 11ms)1.4
Contactor Open (g)6
Contactor Closed at Coil (g)10
Terminal Capacity - Main Contacts (AWG)1 or 2 x (18 to 12)
Screw DriverPhillips #2
Tightening Torque (lb-in)10
Environmental Conditions
Ambient TemperatureStorage: -67 to 176°F (-55 to 80°C), Operating: -4 to 140°F (-20 to 60°C)
Climatic WithstandAccording to IEC 60680-2
Pollution Degree3
Mounting35mm DIN-rail Acc. DIN EN 50 022
Weight (lb)0.42

UL HP Ratings (AC3 Motor Load)

Single Phase
115V1/3HP (7.2A)
230V3/4HP (9A)
Three Phase
230V1-1/2HP (7A)
460V5HP (7A)
575V5HP (9A)
Optional Overload RelayIMOL-16S

Control Circuit Ratings

Standard Voltages12 to 660 (60Hz)
Coil Operating Limits
Monofrequency Coils (NO LOAD) (V)0.85 to 1.1
Pick-up (V)0.40 to 0.76 (AC-60Hz)
Drop-out (V)0.25 to 0.65 (AC-60Hz)
Coil Consumption (Single coils)
Sealed (VA)2.5 to 3.5
Inrush (VA)35
Power Factor
Closed (Cos ɸ)0.28
Opened (Cos ɸ)0.85
Operating Time
Coil Energization - N.O. (ms)8 to 20 (AC-60Hz)
Coil De-energization - N.O. (ms)5 to 15 (AC-60Hz)

Related Items

Application Notes

TitleSummaryRelated Links
AN-MC-005

2 and 3-Wire Motor Control Circuits

Explains the application and wiring of 2 Wire and 3 wire motor control circuits...

Ratings & Reviews

No reviews available

Be the first to Write a Review

Ratings & Reviews

No reviews available

Be the first to Write a Review