Specifications

FMX Contactor, 18A, 3 Pole, 600V, Screw Clamp Terminals, Aux: 1NO, Coil: 400-415/480VAC, 50/60Hz

  • 3/4HP to 75HP
  • DIN-rail mountable up to 105A frame
  • UL508 Listed
  • UL and CE Certified
  • IEC 60947
  • 1 year warranty

UL HP Ratings (AC3 Motor Load)

Single Phase
115V1HP (16A)
230V3HP (17A)
Three Phase
200V5HP (17.5A)
230V5HP(15.2A)
460V10HP (14A)
575V15HP(17A)
Optional Overload RelayIOL-25S

General Specifications

Contactor Frame Size18A
Rated Insulation VoltageUL/CSA: 600V
IEC/VDE 0660: 1000V
Rated Impulse Voltage
IEC60947-1
6kV
Degree of ProtectionMain Terminals: IP20
Coil Terminals: IP20
Auxiliary Terminals: IP20
Rated Operating Frequency25 to 400 Hz
Vibration Resistance
(5 to 200Hz)
Contactor Open: 3g
Contactor Closed at Coil: 6g
Mechanical Endurance10,000,000 (AC Coil) Operations
Electrical Endurance (AC-3)1,200,000 Operations
Shock Resistance
(1/2 Sine Wave = 11ms)
Contactor Open: 8g
Contactor Closed at Coil: 12g
SCCR5kA
Terminal Capacity
(UL /CSA)
Stranded / Solid: 1 or 2
14 - 10AWG
Power Terminals Screw DriverPhilips #2
Tightening Torque15 lb-in
Environmental ConditionsAmbient Storage Temperature: -67° to 176°F (-55° to 80°C)
Operating Ambient Temperature : -13° to 131°F (-25° to 55°C)
Climatic Withstand: According to IEC 60680-2
Pollution Degree: 3
Mounting: 35mm DIN-rail Acc. DIN EN50 022
Dimensions3.189"H x 1.772"W x 3.362"D
(81mm H x 45mm W x 85.4mm D)
Weight0.79 lbs
Warranty1.5 Years
Built-In Auxiliary ContactsIC330-09S to 18S Frame Sizes
Rated Insulation VoltageUL / CSA: 600V
IEC VDE 0660: 690V
Rated Operating VoltageUL / CSA: 600V
IEC VDE 0660: 690V
Rated Thermal Current≤ 131°F(≤55°C): 10A
Rated Operating Current
IEC 60947-5-1 / AC-15
110-172V: 10A
220-240V: 10A
380-400V: 6A
415-450V: 5A
500V: 4A
660-690V: 2A
UL / CSAA600
Rated Operating Current
IEC 60947-5-1 /DC-13
24V: 6A
48V: 4A
110V: 2A
220V: 0.7A
440V: 0.35A
UL CSAP600
Minimum Switching Capacity17V / 5mA
Electrical Endurance 1,000,000 Operations
Mechanical Endurance10,000,000
Guaranteed Non-overlap Time1.5ms
Insulation Resistance>10MΩ

Control Circuit Ratings

AC Coil Voltage Class480VAC (60Hz)
400 to 415VAC (50Hz)
Voltage Range480VAC (60Hz): 384 to 528VAC
400 to 415VAC (50Hz): 320 to 456.5VAC
Coil Operating Limits480VAC Pick-up : 192 to 364.8VAC (60Hz)
400 to 415VAC Pick-up : 160 to 315.4VAC (50Hz)
480VAC Drop-out: 120 to 312VAC (60Hz)
400 to 415VAC Drop-out: 100 to 269.75VAC (50Hz)
Coil Consumption (Single Coils)Sealed: 5.5 to 9.3VA
Inrush: 70.0VA
Heat Loss2.6W
Power FactorSealed: 0.28 Cosɸ
Inrush: 0.85 Cosɸ
Operating TimeCoil Energization-N.O. : 8 to 20ms
Coil De-energization-N.O. : 6 to 13ms

Related Items