PCQ107H, Pool and Spa Mtr, 3/4HP, 3600RPM, K48Y, 115/230V, 11.2/5.6 FLA, 1PH, Square Flange, ODP
PCQ107H, Pool and Spa Mtr, 3/4HP, 3600RPM, K48Y, 115/230V, 11.2/5.6 FLA, 1PH, Square Flange, ODP
WEG Pool and Spa Motor, 3/4HP, 3600RPM, K48Y Frame, 115/230V, 11.2/5.6 FLA, 60Hz, Single Phase, Square Flange, ODP, Start Capacitor, High Service Factor-Full Rate: Service Factor 1.65
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: PCQ107H
Weight: 24 lbs.
Made in: Brazil
$288.30
SKU:PCQ107H
Specifications
WEG Pool and Spa Motor, 3/4HP, 3600RPM, K48Y Frame, 115/230V, 11.2/5.6 FLA, 60Hz, Single Phase, Square Flange, ODP, Start Capacitor, High Service Factor-Full Rate: Service Factor 1.65
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Single -phase, II pole, 60Hz
- Voltage: 115-230V or 230V
- Cast iron C-face or aluminum square flange
- Open Drip Proof (ODP) IP21
- Dual compartment up to 2 1/2HP
- 50°C ambient
- Class 'B' insulation
- CCW (pump end) - non reversible
- AISI 316 stainless steel shaft
- Automatic overload protection
- Threaded shaft
- Internal and external grounding
- Terminal box threaded NPT 1/2"
- D.E. sealed ball bearings
- D.E. endshield sealing - V-ring
- Epoxy coating
- '1081' design
Specifications
| Phase | Single Phase |
| Frame | K48Y |
| Output | 3/4 HP |
| Poles | 02 |
| Frequency | 60 Hz |
| Rated speed | 3510 rpm |
| Slip | 2.50 % |
| Full Voltage - No Cables | 115/230 V |
| Rated Current | 11.2/5.60 A |
| LR Amperes | 70.6/35.3 A |
| LRC | 6.3x(Code M) |
| No Load Current | 8.30/4.15 A |
| Rated Torque | 1.12 ft.lb |
| Locked Rotor Torque | 190 % |
| Breakdown Torque | 340 % |
| Insulation Class | B |
| Service Factor | 1.65 |
| Moment of Inertia | 0.0297 sq.ft.lb |
| Design | - |
| Locked Rotor Time | 10s (cold) 6s (hot) |
| Temperature Rise | 70 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 50 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP21 |
| Altitude | 1000 m |
| Cooling Method | ODP Open Drip Proof Open Motor |
| Mounting | F-1 |
| Rotation Direction | Counter Clockwise |
| Noise Level | 58.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Steel Plate |
| Front Bearing Shielding | 2RS |
| Front Bearing Size | 6203 |
| Front Bearing Type | Ball |
| Front Sealing Type | Lip Seal |
| Rear Bearing Shielding | 2RS |
| Rear Bearing Size | 6203 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | N/A |
| VFD Turndown CT | N/A |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |