E13236EP3YAX315SMF3W, AC Mtr, TEFC, F3 , 3PH, 175 HP, 132 kW, 3000 RPM, 315S/M NEMA, Ex nA, 380-415/660-690//440-460V, 50//60 Hz

E13236EP3YAX315SMF3W, AC Mtr, TEFC, F3 , 3PH, 175 HP, 132 kW, 3000 RPM, 315S/M NEMA, Ex nA, 380-415/660-690//440-460V, 50//60 Hz

WEG AC Motor, Cast Iron Frame, TEFC, F3 Mount, 3 PH, 175 HP, 132 kW, 3000 RPM, 315S/M NEMA Frame, Ex nA, 1.00 Service Factor, 380-415/660-690//440-460V, 50//60 Hz. **Must Ship LTL Truck Freight**

*Images are for illustrative purposes and may not represent the actual configuration of the product.

Item: E13236EP3YAX315SMF3W
(0) No Reviews yet
Weight: 2217 lbs.
Made in: Brazil
Must Ship LTL Truck Freight
$28,130.85
Drop Ship Item
SKU:E13236EP3YAX315SMF3W

Typically Ships Within 1 Business Day

Specifications

WEG AC Motor, Cast Iron Frame, TEFC, F3 Mount, 3 PH, 175 HP, 132 kW, 3000 RPM, 315S/M NEMA Frame, Ex nA, 1.00 Service Factor, 380-415/660-690//440-460V, 50//60 Hz. **Must Ship LTL Truck Freight**

*Images are for illustrative purposes and may not represent the actual configuration of the product.

  • 1.25 service factor for 60 Hz operation (IE3)
  • 1.15 service factor for 60 Hz operation (IE2)
  • Optimized ventilation system for cooler operation and reduced noise levels
  • Solid base for reduced vibration levels (Cast iron frames)
  • Frames 225 and up can easily be F1 (B3L) converted by simply rotating the terminal box adapter or F3 by removing it
  • Aluminum frames have removable feet for easy F1, F2 and F3 (B3L, B3R, B3T) conversion
  • Terminal blocks
  • Class F insulation (impregnation resin and magnet wire are class H)
  • F2 mounted as standard (F1 convertible)
  • Stainless steel nameplate - laser etched with high contrast background
  • Regreasable ball bearings (Frames 160 and up)
  • Gasketed conduit box
  • Class I, Div, 2, Groups A, B, C & D - T3, Class II, Div 2, Groups F & G - T3C (Cast iron frames only)
  • Suitable for WYE/Delta Start (W and Y voltage code motors)

Specifications

PhaseThree Phase
Frame315S/M
Output132 kW
Poles02
Frequency50 Hz
Rated speed2975 rpm
Slip0.83 %
Full Voltage - No Cables380-415/660//440-460 V
Rated Current235/135 A
LR Amperes1598/920 A
LRC -
No Load Current 57.0/32.8 A
Rated Torque313 ft.lb
Locked Rotor Torque180 %
Breakdown Torque260 %
Insulation ClassF
Service Factor1
Moment of Inertia46.4 sq.ft.lb
DesignN
Locked Rotor Time37s (cold) 21s (hot)
Temperature Rise80 K
Duty CycleS1
Maximum Room Temperature40 °C
Minimum Room Temperature-20 °C
Degree of ProtectionIP55
Altitude1000 m
Cooling MethodTEFC Totally Enclosed Fan Cooled
MountingF-3
Rotation DirectionBoth
Noise Level77.0 dB(A)
Starting MethodDirect
Enclosure MaterialIron
Front Bearing ShieldingC3
Front Bearing Size6314
Front Bearing TypeBall
Front Sealing TypeW Seal
Rear Bearing ShieldingC3
Rear Bearing Size6314
Rear Bearing TypeBall
Rear Sealing TypeNo Rear Sealing
Grease TypeMobil Polyrex EM
VFD Turndown VT10:1
VFD Turndown CT2:1

Application Notes

TitleSummaryRelated Links
AN-GEN-004

Determining Motor Full Load Amps (FLA)

How to determine your motor’s FLA.

Ratings & Reviews

No reviews available

Be the first to Write a Review

Ratings & Reviews

No reviews available

Be the first to Write a Review