30009ET3GKD586/7-W22, AC Mtr, Crusher Duty, TEFC, 586/7, Footed, 3 Phase, 900 RPM, 460V, 356 FLA, 300 HP

30009ET3GKD586/7-W22, AC Mtr, Crusher Duty, TEFC, 586/7, Footed, 3 Phase, 900 RPM, 460V, 356 FLA, 300 HP

WEG AC Motor, NEMA Premium Efficiency, Crusher Duty, TEFC, 586/7 Frame, Cast Iron, Foot Mount, 3 Phase, 900 RPM, 460V, 356 FLA, 300 HP

*Images are for illustrative purposes and may not represent the actual configuration of the product.

Item: 30009ET3GKD586/7-W22
(0) No Reviews yet
Weight: 5696 lbs.
Made in: Brazil
Must Ship LTL Truck Freight
$53,384.55
Drop Ship Item
SKU:30009ET3GKD586/7-W22

Typically Ships Within 1 Business Day

Specifications

WEG AC Motor, NEMA Premium Efficiency, Crusher Duty, TEFC, 586/7 Frame, Cast Iron, Foot Mount, 3 Phase, 900 RPM, 460V, 356 FLA, 300 HP

*Images are for illustrative purposes and may not represent the actual configuration of the product.

  • 50/60 Hz rated (380V on Nameplate – 400/415 available)
  • Rated 50 Hz at same Horsepower up to 250HP 1.0 Service Factor for 2, 4 & 6 Pole motors
  • Class F insulation (Impregnation Resin and Magnet wire are class H)
  • NEMA design A. All ratings exceed NEMA design C torque
  • F1 Mounted (F2 convertible). Frames 447T and up can easily be F2 converted by simply rotating the terminal box adapter
  • Stainless Steel Nameplate – Laser etched with high contrast background
  • Regreasable ball bearings
  • Gasketed conduit box
  • Class I, Div. 2, Groups A, B, C & D – T3, Class II, Div. 2, Groups F & G – T3C

Specifications

PhaseThree Phase
Frame586/7T
Output300 HP
Poles08
Frequency60 Hz
Rated speed895 rpm
Slip0.56 %
Full Voltage - No Cables460 V
Rated Current356 A
LR Amperes2670 A
LRC7.5x(Code H)
No Load Current 150 A
Rated Torque1760 ft.lb
Locked Rotor Torque200 %
Breakdown Torque229 %
Insulation ClassF
Service Factor1.15
Moment of Inertia -
DesignNone
Locked Rotor Time72s (cold) 40s (hot)
Temperature Rise80 K
Duty CycleS1
Maximum Room Temperature40 °C
Minimum Room Temperature-20 °C
Degree of ProtectionIP55
Altitude1000 m
Cooling MethodTEFC Totally Enclosed Fan Cooled
MountingF-1
Rotation DirectionBoth
Noise Level75.0 dB(A)
Starting MethodDirect
Enclosure MaterialIron
Front Bearing ShieldingC3
Front Bearing SizeNU-322
Front Bearing TypeRoller
Front Sealing TypeTaconite Labyrinth
Rear Bearing ShieldingC3
Rear Bearing Size6319
Rear Bearing TypeBall
Rear Sealing TypeNo Rear Sealing
Grease TypeMobil Polyrex EM
VFD Turndown VT1000:1
VFD Turndown CT6:1

Application Notes

TitleSummaryRelated Links
AN-GEN-004

Determining Motor Full Load Amps (FLA)

How to determine your motor’s FLA.

Ratings & Reviews

No reviews available

Be the first to Write a Review

Ratings & Reviews

No reviews available

Be the first to Write a Review