03012ET3Y225S/M-W22, 3 PH IEC Tru-Metric - TEFC 40 HP, 1200/1000 RPM, 30 kW, 225S/M NEMA, Footed, 460//380-415/660-690V. Can be fitted with C-Flange kit FLC-E360-314-W22, or D-Flange kit FLF-IM225-W22
03012ET3Y225S/M-W22, 3 PH IEC Tru-Metric - TEFC 40 HP, 1200/1000 RPM, 30 kW, 225S/M NEMA, Footed, 460//380-415/660-690V. Can be fitted with C-Flange kit FLC-E360-314-W22, or D-Flange kit FLF-IM225-W22
WEG Three-Phase W22 IEC Tru-Metric - TEFC (IP55) Cast Iron Frame, 40 HP, 1200/1000 RPM, 30 kW, 225S/M NEMA Frame, Footed, 1.25 Service Factor, 460//380-415/660-690V. Can be fitted with C-Flange kit FLC-E360-314-W22, or D-Flange kit FLF-IM225-W22
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Specifications
WEG Three-Phase W22 IEC Tru-Metric - TEFC (IP55) Cast Iron Frame, 40 HP, 1200/1000 RPM, 30 kW, 225S/M NEMA Frame, Footed, 1.25 Service Factor, 460//380-415/660-690V. Can be fitted with C-Flange kit FLC-E360-314-W22, or D-Flange kit FLF-IM225-W22
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Specifications
| Phase | Three Phase |
| Frame | 225S/M |
| Output | 40 HP |
| Poles | 06 |
| Frequency | 60 Hz |
| Rated speed | 1185 rpm |
| Slip | 1.25 % |
| Full Voltage - No Cables | 460//380-415 V |
| Rated Current | 47.6 A |
| LR Amperes | 405 A |
| LRC | - |
| No Load Current | 20.9 A |
| Rated Torque | 177 ft.lb |
| Locked Rotor Torque | 270 % |
| Breakdown Torque | 330 % |
| Insulation Class | F |
| Service Factor | 1.25 |
| Moment of Inertia | 22.7 sq.ft.lb |
| Design | N |
| Locked Rotor Time | 54s (cold) 30s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-2 |
| Rotation Direction | Both |
| Noise Level | 66.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Iron |
| Front Bearing Shielding | C3 |
| Front Bearing Size | 6314 |
| Front Bearing Type | Ball |
| Front Sealing Type | W Seal |
| Rear Bearing Shielding | C3 |
| Rear Bearing Size | 6314 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 12:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |