03009ET3Y250S/M-W22, AC Mtr, IEC Tru-Metric TEFC, 250S/M, Footed, 3 Phase, 900 RPM, 460V, 50.9 FLA, 40 HP
03009ET3Y250S/M-W22, AC Mtr, IEC Tru-Metric TEFC, 250S/M, Footed, 3 Phase, 900 RPM, 460V, 50.9 FLA, 40 HP
WEG AC Motor, NEMA Premium Efficiency, IEC Tru-Metric , TEFC, 250S/M Frame, Cast Iron, Foot Mount, 3 Phase, 900 RPM, 460V, 50.9 FLA, 40 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Specifications
WEG AC Motor, NEMA Premium Efficiency, IEC Tru-Metric , TEFC, 250S/M Frame, Cast Iron, Foot Mount, 3 Phase, 900 RPM, 460V, 50.9 FLA, 40 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- 60 Hz (1.15 service factor) and 50 Hz (1.0 service factor)
- Class F insulation (Impregnation Resin and Magnet wire are class H)
- F2 mounted as standard (F1 convertible)
- Stainless Steel Nameplate – Laser etched with High contrast background
- Regreasable ball bearings (Frames 160 and up)
- Gasketed conduit box
- Class I, Div. 2, Groups A, B, C & D – T3, Class II, Div. 2, Groups F & G – T3C (Cast Iron Frames only)
- Suitable for WYE/Delta Start (W and Y voltage code motors)
Specifications
| Phase | Three Phase |
| Frame | 250S/M |
| Output | 40 HP |
| Poles | 08 |
| Frequency | 60 Hz |
| Rated speed | 890 rpm |
| Slip | 1.11 % |
| Full Voltage - No Cables | 460//380-415 V |
| Rated Current | 51.6 A |
| LR Amperes | 341 A |
| LRC | - |
| No Load Current | 25.2 A |
| Rated Torque | 236 ft.lb |
| Locked Rotor Torque | 220 % |
| Breakdown Torque | 260 % |
| Insulation Class | F |
| Service Factor | 1.25 |
| Moment of Inertia | 33.9 sq.ft.lb |
| Design | N |
| Locked Rotor Time | 72s (cold) 40s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-2 |
| Rotation Direction | Both |
| Noise Level | 60.0 dB(A) |
| Starting Method | Direct |
| Enclosure Material | Iron |
| Front Bearing Shielding | C3 |
| Front Bearing Size | 6314 |
| Front Bearing Type | Ball |
| Front Sealing Type | W Seal |
| Rear Bearing Shielding | C3 |
| Rear Bearing Size | 6314 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 12:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |