01018ET3P215JM-W22, AC Mtr, Close-coupled Pump, TEFC, 215JM, C-Face w/Footed, 3 Phase, 1800 RPM, 200V, 28.5 FLA, 10 HP
01018ET3P215JM-W22, AC Mtr, Close-coupled Pump, TEFC, 215JM, C-Face w/Footed, 3 Phase, 1800 RPM, 200V, 28.5 FLA, 10 HP
WEG AC Motor, NEMA Premium Efficiency, Close-coupled Pump, TEFC, 215JM Frame, Cast Iron, C-Face w/foot Mount, 3 Phase, 1800 RPM, 200V, 28.5 FLA, 10 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Specifications
WEG AC Motor, NEMA Premium Efficiency, Close-coupled Pump, TEFC, 215JM Frame, Cast Iron, C-Face w/foot Mount, 3 Phase, 1800 RPM, 200V, 28.5 FLA, 10 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- NEMA Premium Efficiency Level according to NEMA MG-1
- Three-phase, 60 Hz
- Degree of protection: IP55 – TEFC – Totally enclosed fan cooled
- Rated output: 1 HP to 75 HP
- Number of poles: 2 and 4
- Frame sizes: 143JM to 364/5JM
- FC-200 Cast iron frames
- Voltage: 208-230/460, 460V or 575V
- Service Factor: 1.25
- F-1 mount
- Steel made fan cover for frames 143JM to 215JM and cast iron made for 254JM and above
- Automatic drain plastic plug for frames 143JM to 215JM and rubber closed drain plug 254JM and above
- V’ring seals for frames 143JM to 326JM and Oil seal for frame 364/5JM
- Class “F” insulation with class “B” (80ºC) temperature rise
- Simple grounding (T-box interior and frame) for frames 143JM to 326JM and double grounding + additional (1 at T-box and 3 at frame) for frame 364/5JM
- Grease nipples for frame 364/5JM
- Continuous Duty (S1)
- Painting plan: 207A for frames 143JM to 215JM and 203A for frame 254JM and above
- Color: RAL 5009 – Blue
- Without thermal protection
- Design B
Specifications
| Phase | Three Phase |
| Frame | 213/5 |
| Output | 10 HP |
| Poles | 04 |
| Frequency | 60 Hz |
| Rated speed | 1765 rpm |
| Slip | 1.94 % |
| Full Voltage - No Cables | 200 V |
| Rated Current | 28.5 A |
| LR Amperes | 183 A |
| LRC | 6.4x(Code H) |
| No Load Current | 13.0 A |
| Rated Torque | 29.8 ft.lb |
| Locked Rotor Torque | 200 % |
| Breakdown Torque | 295 % |
| Insulation Class | F |
| Service Factor | 1.25 |
| Moment of Inertia | 1.51 sq.ft.lb |
| Design | B |
| Locked Rotor Time | 30s (cold) 17s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-1 |
| Rotation Direction | Both |
| Noise Level | 58.0 dB(A) |
| Starting Method | Direct |
| Enclosure Material | Iron |
| Front Bearing Shielding | Z-C3 |
| Front Bearing Size | 6309 |
| Front Bearing Type | Ball |
| Front Sealing Type | V Ring |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6207 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 20:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |