00118ET3E143JP-SG, AC Mtr, ODP, 3PH, 1 HP, 0.75 kW, 1800 RPM, 143/5JP NEMA, JM - 3PH, 208-230/460V, 3.3-3/1.5 FLA
00118ET3E143JP-SG, AC Mtr, ODP, 3PH, 1 HP, 0.75 kW, 1800 RPM, 143/5JP NEMA, JM - 3PH, 208-230/460V, 3.3-3/1.5 FLA
WEG AC Motor, Rolled Steel Frame, ODP, AEGIS Installed, 3 PH, 1 HP, 0.75 kW, 1800 RPM, 143/5JP NEMA Frame, JM - Three-Phase, AEGIS Bearing protection ring installed1.15 Service Factor, 208-230/460V, 3.3-3/1.5 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: 00118ET3E143JP-SG
Weight: 43 lbs.
Made in: Brazil
$726.95
SKU:00118ET3E143JP-SG
Specifications
WEG AC Motor, Rolled Steel Frame, ODP, AEGIS Installed, 3 PH, 1 HP, 0.75 kW, 1800 RPM, 143/5JP NEMA Frame, JM - Three-Phase, AEGIS Bearing protection ring installed1.15 Service Factor, 208-230/460V, 3.3-3/1.5 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Rated Output: 1 through 20 HP (Others upon inquiry)
- RPM: 3600 and 1800 (1200 rpm upon inquiry)
- Class F insulation
- Frame Sizes: NEMA 143/5 to 254/6
- Frequency: 60 Hz (dual rated under “E” voltage code: 50 Hz 190-220/380-415V)
- Degree of protection: IP55
- Mounting: F-1
- Doubled shielded ball bearings on frames 143/5 to 213/5T
- AEGIS Bearing protection ring installed
Specifications
| Phase | Three Phase |
| Frame | 143/5 |
| Output | 1 HP |
| Poles | 04 |
| Frequency | 60 Hz |
| Rated speed | 1765 rpm |
| Slip | 1.94 % |
| Full Voltage - No Cables | 208-230/460//190-220/380-415 V |
| Rated Current | 2.94/1.47 A |
| LR Amperes | 25.3/12.6 A |
| LRC | 8.6x(Code M) |
| No Load Current | 1.78/0.890 A |
| Rated Torque | 2.98 ft.lb |
| Locked Rotor Torque | 280 % |
| Breakdown Torque | 300 % |
| Insulation Class | F |
| Service Factor | 1.15 |
| Moment of Inertia | 0.1232 sq.ft.lb |
| Design | B |
| Locked Rotor Time | 34s (cold) 19s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-1 |
| Rotation Direction | Both |
| Noise Level | 52.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Steel Plate |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6206 |
| Front Bearing Type | Ball |
| Front Sealing Type | V Ring |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6203 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 4:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |