00118ES1B56C-S, AC Mtr, 1HP, 1800RPM, 56C, GENERAL PURPOSE - ROLLED STEEL TEFC SINGLE-PHASE, 115/208-230V, 13.6/7.5-6.8 FLA, RIGID BASE - 'C' FACE, RIGID BASE - 'C' FACE, NORMAL STOCK
00118ES1B56C-S, AC Mtr, 1HP, 1800RPM, 56C, GENERAL PURPOSE - ROLLED STEEL TEFC SINGLE-PHASE, 115/208-230V, 13.6/7.5-6.8 FLA, RIGID BASE - 'C' FACE, RIGID BASE - 'C' FACE, NORMAL STOCK
WEG AC MOTOR, 1HP, 1800RPM, 56C FRAME, GENERAL PURPOSE - ROLLED STEEL TEFC (IP55) SINGLE-PHASE, 115/208-230V, 13.6/7.5-6.8 FLA, RIGID BASE - 'C' FACE, 1.15 SERVICE FACTOR, RIGID BASE - 'C' FACE, NORMAL STOCK
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: 00118ES1b56C-S
Weight: 52 lbs.
Made in: Brazil
$416.05
SKU:00118ES1B56C-S
Specifications
WEG AC MOTOR, 1HP, 1800RPM, 56C FRAME, GENERAL PURPOSE - ROLLED STEEL TEFC (IP55) SINGLE-PHASE, 115/208-230V, 13.6/7.5-6.8 FLA, RIGID BASE - 'C' FACE, 1.15 SERVICE FACTOR, RIGID BASE - 'C' FACE, NORMAL STOCK
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Single-phase, II, IV or VI pole, 60Hz
- Voltage: 115/208-230V
- Squirrel cage rotor
- Start capacitor
- NEMA dimensions
- Class ‘B’ insulation (130ºC)
- High starting torque
- Ball Bearings
- Totally enclosed fan cooled (TEFC - IP55)
- Color: RAL 7022 (Dark Gray)
- Continuous Duty (S1), 40ºC ambient
- V-ring slingers on both endshields (for TEFC only)
- Designed to operate in any position (for TEFC only)
Specifications
| Phase | Single Phase |
| Frame | 56 |
| Output | 1 HP |
| Poles | 04 |
| Frequency | 60 Hz |
| Rated speed | 1745 rpm |
| Slip | 3.06 % |
| Full Voltage - No Cables | 115/208-230 V |
| Rated Current | 13.6/7.52-6.80 A |
| LR Amperes | 91.1/50.4-45.6 A |
| LRC | 6.7x(Code M) |
| No Load Current | 9.60/4.14-4.80 A |
| Rated Torque | 3.01 ft.lb |
| Locked Rotor Torque | 280 % |
| Breakdown Torque | 270 % |
| Insulation Class | F |
| Service Factor | 1.15 |
| Moment of Inertia | 0.1037 sq.ft.lb |
| Design | L |
| Locked Rotor Time | 14s (cold) 8s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-1 |
| Rotation Direction | Both |
| Noise Level | 54.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Steel Plate |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6204 |
| Front Bearing Type | Ball |
| Front Sealing Type | V Ring |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6202 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | N/A |
| VFD Turndown CT | N/A |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |