00112ET3E145T-S, AC Mtr, TEFC, 3PH, 1 HP, 0.75 kW, 1200 RPM, 143/5T NEMA, Footed, 208-230/460V, 3.5-3.2/1.6 FLA

00112ET3E145T-S, AC Mtr, TEFC, 3PH, 1 HP, 0.75 kW, 1200 RPM, 143/5T NEMA, Footed, 208-230/460V, 3.5-3.2/1.6 FLA

WEG AC Motor, Rolled Steel Frame, TEFC, 3 PH, 1 HP, 0.75 kW, 1200 RPM, 143/5T NEMA Frame, Foot Mount, 1.15 Service Factor, 208-230/460V, 3.5-3.2/1.6 FLA, 60 Hz.

*Images are for illustrative purposes and may not represent the actual configuration of the product.

Item: 00112ET3E145T-S
(0) No Reviews yet
Weight: 43 lbs.
Made in: Brazil
$511.10
Drop Ship Item
SKU:00112ET3E145T-S

Typically Ships Within 1 Business Day

Specifications

WEG AC Motor, Rolled Steel Frame, TEFC, 3 PH, 1 HP, 0.75 kW, 1200 RPM, 143/5T NEMA Frame, Foot Mount, 1.15 Service Factor, 208-230/460V, 3.5-3.2/1.6 FLA, 60 Hz.

*Images are for illustrative purposes and may not represent the actual configuration of the product.

  • Rated Output: 1 to 25 HP
  • Number of Poles: 2 to 6
  • Class F insulation (B temperature rise)
  • Frame Sizes: NEMA 143/5T to 254/6T
  • Double punched base
  • Rated voltage: 208-230/460 V
  • Frequency: 60 Hz (dual rated 50 Hz 190-220/380-415V)
  • IP55 enclosure
  • F1 Foot mount as standard
  • Aluminum endshields
  • Cast Iron flanges for improved strength (182/4TC and above), Aluminum on 143/5TC frame
  • Internal bolts, giving a clean surface to the motor, avoiding trapping materials and allowing easy paint job after assembly to the load, if required
  • Double shielded ball bearings on frames up to 213/5T. Regreasable ball bearings on 254/6T frame
  • Bearing cap as standard on flanged motors, optional on non-flanged
  • Ambient temperature: -20°C to +40°C
  • 1040/45 carbon steel shaft

Specifications

PhaseThree Phase
Frame143/5T
Output1 HP
Poles06
Frequency60 Hz
Rated speed1145 rpm
Slip4.58 %
Full Voltage - No Cables208-230/460//190-220/380-415 V
Rated Current3.16/1.58 A
LR Amperes18.3/9.16 A
LRC5.8x(Code J)
No Load Current 2.03/1.01 A
Rated Torque4.59 ft.lb
Locked Rotor Torque229 %
Breakdown Torque280 %
Insulation ClassF
Service Factor1.15
Moment of Inertia0.1597 sq.ft.lb
DesignB
Locked Rotor Time55s (cold) 31s (hot)
Temperature Rise80 K
Duty CycleS1
Maximum Room Temperature40 °C
Minimum Room Temperature-20 °C
Degree of ProtectionIP55
Altitude1000 m
Cooling MethodTEFC Totally Enclosed Fan Cooled
MountingF-1
Rotation DirectionBoth
Noise Level50.0 dB(A)
Starting Method-
Enclosure MaterialSteel Plate
Front Bearing ShieldingZZ
Front Bearing Size6205
Front Bearing TypeBall
Front Sealing TypeV Ring
Rear Bearing ShieldingZZ
Rear Bearing Size6203
Rear Bearing TypeBall
Rear Sealing TypeNo Rear Sealing
Grease TypeMobil Polyrex EM
VFD Turndown VT1000:1
VFD Turndown CT4:1

Application Notes

TitleSummaryRelated Links
AN-GEN-004

Determining Motor Full Load Amps (FLA)

How to determine your motor’s FLA.

Ratings & Reviews

No reviews available

Be the first to Write a Review

Ratings & Reviews

No reviews available

Be the first to Write a Review