.5018OT1BW56CFL-S, AC Mtr, General Purpose, ODP, 56C, Rolled C-Face , 1 Phase, 1800 RPM, 115/208-230V, 5.6/3.1-2.8 FLA,.50 HP
.5018OT1BW56CFL-S, AC Mtr, General Purpose, ODP, 56C, Rolled C-Face , 1 Phase, 1800 RPM, 115/208-230V, 5.6/3.1-2.8 FLA,.50 HP
WEG AC Motor, NEMA Premium Efficiency, General Purpose, ODP, 56C Frame, Rolled Steel, C-Face Mount, 1 Phase, 1800 RPM, 115/208-230V, 5.6/3.1-2.8 FLA, .50 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: .5018OT1BW56CFL-S
Weight: 24 lbs.
Made in: Brazil
$333.95
SKU:.5018OT1BW56CFL-S
Specifications
WEG AC Motor, NEMA Premium Efficiency, General Purpose, ODP, 56C Frame, Rolled Steel, C-Face Mount, 1 Phase, 1800 RPM, 115/208-230V, 5.6/3.1-2.8 FLA, .50 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Rated Output: 0.25 to 3 HP
- Number of Poles: 2 to 6
- Class F insulation (B temperature rise)
- Frame Sizes: NEMA 56 and 56H
- Rated voltage: 208-230/460 V
- Frequency: 60 Hz (dual rated 50 Hz 190-220/380-415V)
- IP21 enclosure
- Aluminum endshields and flange
- Internal bolts, giving a clean surface to the motor, avoiding trapping materials and allowing easy paint job after assembly to the load, if required
- Double shielded ball bearings
- Ambient temperature: -20 °C to +40 °C
- 1040/45 carbon steel shaft
Specifications
| Phase | Single Phase |
| Frame | W56 |
| Output | 0.5 HP |
| Poles | 04 |
| Frequency | 60 Hz |
| Rated speed | 1730 rpm |
| Slip | 3.89 % |
| Full Voltage - No Cables | 115/208-230 V |
| Rated Current | 4.86/3.04-2.43 A |
| LR Amperes | 37.4/23.4-18.7 A |
| LRC | 7.7x(Code K) |
| No Load Current | 2.70/1.16-1.35 A |
| Rated Torque | 1.52 ft.lb |
| Locked Rotor Torque | 300 % |
| Breakdown Torque | 270 % |
| Insulation Class | F |
| Service Factor | 1.25 |
| Moment of Inertia | 0.0520 sq.ft.lb |
| Design | N |
| Locked Rotor Time | 27s (cold) 15s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP21 |
| Altitude | 1000 m |
| Cooling Method | ODP Open Drip Proof Open Motor |
| Mounting | F-1 |
| Rotation Direction | Both |
| Noise Level | 50.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Steel Plate |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6203 |
| Front Bearing Type | Ball |
| Front Sealing Type | No Sealing |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6202 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | N/A |
| VFD Turndown CT | N/A |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |