.5018OS1DEC56, AC Mtr, ODP, Split Phase Mtr, 1 PH, 0.5 HP, 0.37 kW, 1800 RPM, 56 NEMA,, 240V, 4.80 FLA

WEG AC Motor, Rolled Steel Frame, ODP, Automatic Reset Thermal Overload Protector, Split Phase Motor, 1 PH, 0.5 HP, 0.37 kW, 1800 RPM, 56 NEMA Frame, Single-Phase - Evaporative Cooler, 1.00 Service Factor, 240V, 4.80 FLA, 60 Hz.

*Images are for illustrative purposes and may not represent the actual configuration of the product.

Weight: 20 lbs.Made in: Brazil

.5018OS1DEC56, AC Mtr, ODP, Split Phase Mtr, 1 PH, 0.5 HP, 0.37 kW, 1800 RPM, 56 NEMA,, 240V, 4.80 FLA

WEG AC Motor, Rolled Steel Frame, ODP, Automatic Reset Thermal Overload Protector, Split Phase Motor, 1 PH, 0.5 HP, 0.37 kW, 1800 RPM, 56 NEMA Frame, Single-Phase - Evaporative Cooler, 1.00 Service Factor, 240V, 4.80 FLA, 60 Hz.

*Images are for illustrative purposes and may not represent the actual configuration of the product.

Weight: 20 lbs.Made in: Brazil
Drop Ship
$182.90
QuantityPrice


Typically Ships Within 1 Business Day

Specifications

WEG AC Motor, Rolled Steel Frame, ODP, Automatic Reset Thermal Overload Protector, Split Phase Motor, 1 PH, 0.5 HP, 0.37 kW, 1800 RPM, 56 NEMA Frame, Single-Phase - Evaporative Cooler, 1.00 Service Factor, 240V, 4.80 FLA, 60 Hz.

*Images are for illustrative purposes and may not represent the actual configuration of the product.

  • Single-phase, II, IV or VI pole, 60Hz
  • Voltage: 115/208-230V
  • Squirrel cage rotor
  • Start capacitor
  • NEMA dimensions
  • Class “B” insulation (130ºC)
  • High starting torque
  • Ball Bearings
  • Totally enclosed fan cooled (TEFC - IP55)
  • Color: RAL 7022 (Dark Gray)
  • Continuous Duty (S1), 40ºC ambient
  • V-ring slingers on both endshields
  • Designed to operate in any position
  • Manual thermal overload protection

Specifications

PhaseSingle Phase
FrameE56Z
Output0.5 HP
Poles04
Frequency60 Hz
Rated speed1725 rpm
Slip4.17 %
Full Voltage - No Cables240 V
Rated Current4.80 A
LR Amperes30.2 A
LRC6.3x(Code R)
No Load Current 4.30 A
Rated Torque1.51 ft.lb
Locked Rotor Torque150 %
Breakdown Torque240 %
Insulation ClassB
Service Factor1
Moment of Inertia -
Design-
Locked Rotor Time10s (cold) 6s (hot)
Temperature Rise80 K
Duty CycleS1
Maximum Room Temperature40 °C
Minimum Room Temperature-20 °C
Degree of ProtectionIP21
Altitude1000 m
Cooling MethodODP Open Drip Proof Open Motor
MountingF-1
Rotation DirectionClockwise
Noise Level -
Starting MethodDirect
Enclosure MaterialSteel Plate
Front Bearing ShieldingZZ
Front Bearing Size6201
Front Bearing TypeBall
Front Sealing TypeNo Sealing
Rear Bearing ShieldingZZ
Rear Bearing Size6201
Rear Bearing TypeBall
Rear Sealing TypeNo Rear Sealing
Grease TypeMobil Polyrex EM
VFD Turndown VTN/A
VFD Turndown CTN/A

Ratings & Reviews

No reviews available

Be the first to Write a Review