.5012ES3E56-S, AC Mtr, TEFC, 3PH, 0.5 HP, 0.37 kW, 1200 RPM, 56 NEMA, Footed, 208-230/460V, 2.2-2/1 FLA
.5012ES3E56-S, AC Mtr, TEFC, 3PH, 0.5 HP, 0.37 kW, 1200 RPM, 56 NEMA, Footed, 208-230/460V, 2.2-2/1 FLA
WEG AC Motor, Rolled Steel Frame, TEFC, 3 PH, 0.5 HP, 0.37 kW, 1200 RPM, 56 NEMA Frame, Foot Mount, 1.15 Service Factor, 208-230/460V, 2.2-2/1 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: .5012ES3E56-S
Weight: 30 lbs.
Made in: Brazil
$396.80
SKU:.5012ES3E56-S
Specifications
WEG AC Motor, Rolled Steel Frame, TEFC, 3 PH, 0.5 HP, 0.37 kW, 1200 RPM, 56 NEMA Frame, Foot Mount, 1.15 Service Factor, 208-230/460V, 2.2-2/1 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Rated Output: 0.25 to 3 HP
- Number of Poles: 2 to 6
- Class F insulation (B temperature rise)
- Frame Sizes: NEMA 56 and 56H
- Rated voltage: 208-230/460 V
- Frequency: 60 Hz (dual rated 50 Hz 190-220/380-415V)
- IP55 enclosure
- F1 foot mount as standard
- Aluminum endshields and flange
- Internal bolts, giving a clean surface to the motor, avoiding trapping materials and allowing easy paint job after assembly to the load, if required
- Double shielded ball bearings
- Ambient temperature: -20°C to +40°C
- 1040/45 carbon steel shaft
Specifications
| Phase | Three Phase |
| Frame | 56 |
| Output | 0.5 HP |
| Poles | 06 |
| Frequency | 60 Hz |
| Rated speed | 1160 rpm |
| Slip | 3.33 % |
| Full Voltage - No Cables | 208-230/460//190-220/380-415 V |
| Rated Current | 2.19-1.98/0.992 A |
| LR Amperes | 11.8-10.7/5.36 A |
| LRC | 5.4x(Code K) |
| No Load Current | 1.33-1.54/0.772 A |
| Rated Torque | 2.26 ft.lb |
| Locked Rotor Torque | 210 % |
| Breakdown Torque | 300 % |
| Insulation Class | F |
| Service Factor | 1.15 |
| Moment of Inertia | 0.1065 sq.ft.lb |
| Design | None |
| Locked Rotor Time | 39s (cold) 22s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-1 |
| Rotation Direction | Both |
| Noise Level | 50.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Steel Plate |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6203 |
| Front Bearing Type | Ball |
| Front Sealing Type | V Ring |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6202 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 10:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |