.2512OT3E56-S, AC Mtr, General Purpose, ODP, 56, Rolled Footed, 3 Phase, 1200 RPM, 208-230/460V, 1.2-1.1/0.55 FLA,.25 HP
.2512OT3E56-S, AC Mtr, General Purpose, ODP, 56, Rolled Footed, 3 Phase, 1200 RPM, 208-230/460V, 1.2-1.1/0.55 FLA,.25 HP
WEG AC Motor, NEMA Premium Efficiency, General Purpose, ODP, 56 Frame, Rolled Steel, Foot Mount, 3 Phase, 1200 RPM, 208-230/460V, 1.2-1.1/0.55 FLA, .25 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: .2512OT3E56-S
Weight: 22 lbs.
Made in: Brazil
$282.60
SKU:.2512OT3E56-S
Specifications
WEG AC Motor, NEMA Premium Efficiency, General Purpose, ODP, 56 Frame, Rolled Steel, Foot Mount, 3 Phase, 1200 RPM, 208-230/460V, 1.2-1.1/0.55 FLA, .25 HP
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Rated Output: 0.25 to 3 HP
- Number of Poles: 2 to 6
- Class F insulation (B temperature rise)
- Frame Sizes: NEMA 56 and 56H
- Rated voltage: 208-230/460 V
- Frequency: 60 Hz (dual rated 50 Hz 190-220/380-415V)
- IP21 enclosure
- F1 foot mount as standard
- Aluminum endshields and flange
- Internal bolts, giving a clean surface to the motor, avoiding trapping materials and allowing easy paint job after assembly to the load, if required
- Double shielded ball bearings
- Ambient temperature: -20 °C to +40 °C
- 1040/45 carbon steel shaft
Specifications
| Phase | Three Phase |
| Frame | 56 |
| Output | 0.25 HP |
| Poles | 06 |
| Frequency | 60 Hz |
| Rated speed | 1160 rpm |
| Slip | 3.33 % |
| Full Voltage - No Cables | 208-230/460//190-220/380-415 V |
| Rated Current | 1.21-1.10/0.549 A |
| LR Amperes | 5.83-5.27/2.64 A |
| LRC | 4.8x(Code K) |
| No Load Current | 0.862-1.00/0.500 A |
| Rated Torque | 1.13 ft.lb |
| Locked Rotor Torque | 210 % |
| Breakdown Torque | 280 % |
| Insulation Class | F |
| Service Factor | 1.35 |
| Moment of Inertia | 0.0622 sq.ft.lb |
| Design | None |
| Locked Rotor Time | 72s (cold) 40s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP21 |
| Altitude | 1000 m |
| Cooling Method | ODP Open Drip Proof Open Motor |
| Mounting | F-1 |
| Rotation Direction | Both |
| Noise Level | 50.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Steel Plate |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6203 |
| Front Bearing Type | Ball |
| Front Sealing Type | No Sealing |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6202 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 5:1 |
| VFD Turndown CT | 5:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |