SSR19-60240CS, SSR, 60A SPST, OUT: 48-280VAC, SCR, IN: 90-280VAC
SSR19-60240CS, SSR, 60A SPST, OUT: 48-280VAC, SCR, IN: 90-280VAC
El.Co Solid State Relay, "Hockey Puck" Style, Panel Mount, 60A SPST, Zero Cross NO, Output: 48-280VAC, Back-to-back SCR, Input: 90-280VAC, with LED
Item: SSR19-60240CS
Weight: 0.3 lbs.
Made in: India
Quantity Pricing
1+
$37.35
5+
$36.60
10+
$35.48
20+
$34.55
$37.35
SKU:SSR19-60240CS
Specifications
El.Co Solid State Relay, "Hockey Puck" Style, Panel Mount, 60A SPST, Zero Cross NO, Output: 48-280VAC, Back-to-back SCR, Input: 90-280VAC, with LED
- 48-280VAC output to suit a wide range of applications
- Zero cross switching
- LED indicated presence of input voltage
- Low control current
- Integrated transient voltage protection
- Operating temperature: -22 to 176°F (-30 to 80°C)
- Storage temperature: -22 to 212°F (-30 to 100°C)
- Optional thermal pad available
- Optional heatsink available
- UL File #E234472
GENERAL SPECIFICATIONS
| Maximum Output Current | 60A |
| Input Voltage Range | 90 to 280VAC |
| Output Voltage Range | 48 to 280VAC |
| Control Voltage Range | 90 to 280VAC |
| Control Pick-up Voltage | 90VAC |
| Control Drop-Out Voltage | 10VAC |
| Control Current Range | 25mA (@280VAC/50Hz) |
| Load Voltage Range | 240VAC : 48 to 280VAC |
| Maximum Turn-on Time | Instant Commutation: 1ms Zero crossing Commutation: 1/2 Cycle +1ms AC Control: 40ms |
| Maximum Opening Delay for Zero Crossing | AC Control: 40ms |
| Non-repetitive Surge Peak On-state Current | 60A: 700A |
| I²t Rating | 60A : 2450A²s |
| Non-repetitive Peak Off-state | 48 to 280VAC: 600V peak |
| Maximum Operating Voltage by Varistors | 48 to 280VAC: 300VAC |
| Off-state Leakage Current | 10mA |
| Output Voltage Drop | 1.7 V/ms |
| Critical rate of rise of Off-state Voltage dv/dt | 500V/µs |
| Insulation Voltage | Input / Output : 4000V rms Input / Output / Base : 2500V rms |
| Temperature | Operating: -22° to 176°F (-30 to 80°C) Storage: -22° to 212°F (-30° to 100°C) |
| Certifications | UL and TUV |
| Conformance | EN 60335-1 requirements |