00152OT3E182T-SG, AC Mtr, ODP, 3PH, 1.5 HP, 1.1 kW, 1200 RPM, 182/4T NEMA, 3PH - Footed, 208-230/460V, 5.1-4.6/2.3 FLA
00152OT3E182T-SG, AC Mtr, ODP, 3PH, 1.5 HP, 1.1 kW, 1200 RPM, 182/4T NEMA, 3PH - Footed, 208-230/460V, 5.1-4.6/2.3 FLA
WEG AC Motor, Rolled Steel Frame, ODP, AEGIS Installed, 3 PH, 1.5 HP, 1.1 kW, 1200 RPM, 182/4T NEMA Frame, Three-Phase - Foot Mount, 1.15 Service Factor, 208-230/460V, 5.1-4.6/2.3 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: 00152OT3E182T-SG
Weight: 63 lbs.
Made in: Brazil
$721.25
SKU:00152OT3E182T-SG
Specifications
WEG AC Motor, Rolled Steel Frame, ODP, AEGIS Installed, 3 PH, 1.5 HP, 1.1 kW, 1200 RPM, 182/4T NEMA Frame, Three-Phase - Foot Mount, 1.15 Service Factor, 208-230/460V, 5.1-4.6/2.3 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Rated Output: 1 through 100HP
- RPM: 3600, 1800 and 1200
- Class F insulation
- Frame Sizes: NEMA 143/5 through 404/5
- Frequency: 60 Hz (dual rated under “E” voltage code: W01 as 50 Hz 190-220/380-415V; W40 as 50Hz 190/380V)
- Degree of protection: IP21 (W01) / IP23 (W40)
- Mounting: F-1
- Doubled shielded ball bearings on frames 143/5 to 213/5T
- AEGIS Bearing protection ring installed
Specifications
| Phase | Three Phase |
| Frame | 182/4T |
| Output | 1.5 HP |
| Poles | 06 |
| Frequency | 60 Hz |
| Rated speed | 1165 rpm |
| Slip | 2.92 % |
| Full Voltage - No Cables | 208-230/460//190-220/380-415 V |
| Rated Current | 4.50/2.25 A |
| LR Amperes | 29.3/14.6 A |
| LRC | 6.5x(Code J) |
| No Load Current | 2.74/1.37 A |
| Rated Torque | 6.76 ft.lb |
| Locked Rotor Torque | 200 % |
| Breakdown Torque | 310 % |
| Insulation Class | F |
| Service Factor | 1.15 |
| Moment of Inertia | 0.2178 sq.ft.lb |
| Design | B |
| Locked Rotor Time | 82s (cold) 46s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP21 |
| Altitude | 1000 m |
| Cooling Method | ODP Open Drip Proof Open Motor |
| Mounting | F-1 |
| Rotation Direction | Both |
| Noise Level | 52.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Steel Plate |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6206 |
| Front Bearing Type | Ball |
| Front Sealing Type | No Sealing |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6205 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 5:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |