00336ET3H182JM-S, AC Mtr, TEFC, 3PH, 3 HP, 2.2 kW, 3600 RPM, 182/4JM NEMA, JM - 3PH, 575V, 2.9 FLA



00336ET3H182JM-S, AC Mtr, TEFC, 3PH, 3 HP, 2.2 kW, 3600 RPM, 182/4JM NEMA, JM - 3PH, 575V, 2.9 FLA
WEG AC Motor, Rolled Steel Frame, TEFC, 3 PH, 3 HP, 2.2 kW, 3600 RPM, 182/4JM NEMA Frame, JM - Three-Phase, 1.15 Service Factor, 575V, 2.9 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Item: 00336ET3H182JM-S
Weight: 71 lbs.
Made in: Brazil
$738.50
SKU:00336ET3H182JM-S
Specifications
WEG AC Motor, Rolled Steel Frame, TEFC, 3 PH, 3 HP, 2.2 kW, 3600 RPM, 182/4JM NEMA Frame, JM - Three-Phase, 1.15 Service Factor, 575V, 2.9 FLA, 60 Hz.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Rated Output: 1 to 25 HP
- Number of Poles: 2 to 6
- Class F insulation (B temperature rise)
- Frame Sizes: 143/5 to 254/6, JM design
- Double punched base
- Rated voltage: 208-230/460 V
- Frequency: 60 Hz (dual rated 50 Hz 190-220/380-415V)
- IP55 enclosure
- F1 foot mount as standard
- Aluminum NDE endshield
- Cast Iron flanges for improved strength (182/4TC and above), Aluminum on 143/5TC frame
- Internal bolts, giving a clean surface to the motor, avoiding trapping materials and allowing easy paint job after assembly to the load, if required
- Double shielded ball bearings on frames up to 213/5T. Regreasable ball bearings on 254/6T frame
- Standard bearing cap in all frames
- Ambient temperature: -20°C to +40°C
- 1040/45 carbon steel shaft
Specifications
Phase | Three Phase |
Frame | 182/4 |
Output | 3 HP |
Poles | 02 |
Frequency | 60 Hz |
Rated speed | - |
Slip | - |
Full Voltage - No Cables | 575 V |
Rated Current | - |
LR Amperes | - |
LRC | - |
No Load Current | - |
Rated Torque | - |
Locked Rotor Torque | - |
Breakdown Torque | - |
Insulation Class | F |
Service Factor | 1.15 |
Moment of Inertia | - |
Design | B |
Locked Rotor Time | - |
Temperature Rise | 80 K |
Duty Cycle | S1 |
Maximum Room Temperature | 40 °C |
Minimum Room Temperature | -20 °C |
Degree of Protection | IP55 |
Altitude | 1000 m |
Cooling Method | TEFC Totally Enclosed Fan Cooled |
Mounting | F-1 |
Rotation Direction | Both |
Noise Level | - |
Starting Method | - |
Enclosure Material | Steel Plate |
Front Bearing Shielding | ZZ |
Front Bearing Size | 6207 |
Front Bearing Type | Ball |
Front Sealing Type | V Ring |
Rear Bearing Shielding | ZZ |
Rear Bearing Size | 6205 |
Rear Bearing Type | Ball |
Rear Sealing Type | No Rear Sealing |
Grease Type | Mobil Polyrex EM |
VFD Turndown VT | 1000:1 |
VFD Turndown CT | 10:1 |
Application Notes
Title | Summary | Related Links |
---|---|---|
AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |