Micron General Purpose Transformer, Group E, 7.5 kVA Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 208 V; SEC: 120/240 V
Micron General Purpose Transformer, Group D, 7.5 kVA Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 600 V SEC: 120/240 V; FCBN 2-5%
Micron General Purpose Transformer, Group B, 7.5 kVA, Type 1-E, Single-phase, Encapsulated, 50/60Hz (Export Model), PRI: 190/200/208/220/380/400/416/440 V SEC: 110/220 V 50/60 HZ
Micron General Purpose Transformer, Group G, 7.5 kVA Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 120 X 240 V SEC: 120/240 V
Micron General Purpose Transformer, Group A, 750VA, Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 240x480, SEC: 120/240V
Micron General Purpose Transformer, Group E, 0.5 kVA Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 208 V; SEC: 120/240 V
Micron General Purpose Transformer, Group A, 500VA, Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 240x480, SEC: 120/240V
Micron General Purpose Transformer, Group N, 300 kVA Type 3-V, PRI: 600 V TO 208Y/120 V: FCAN: 2-2.5% FCBN: 4-2.5%
Micron General Purpose Transformer, Group M, 300 kVA Type 3-V, PRI: 480 V TO 480Y/277 V: FCAN: 2-2.5% FCBN: 4-2.5%
Micron General Purpose Transformer, Group L, 300 kVA Type 3-V, PRI: 480 V TO 240 V w/ 120 V lighting tap on B phase (center tap capacity limited to 5% of rated kVA) FCAN: 2-2.5% FCBN: 4-2.5 %
Micron General Purpose Transformer, Group J, 300 kVA Type 3-V, PRI: 480 V SEC: 208Y/120 V: FCAN: 2-2.5% FCBN: 4-2.5%
Micron General Purpose Transformer, Group I, 300 kVA Type 3-V, PRI: 240V SEC: 208Y/120 V: FCAN 1-5%: FCBN: 2-5% 240 V
Micron General Purpose Transformer, Group H, 300 kVA Type 3-V, Three-phase, Ventilated, 60Hz, PRI: 280 V SEC: 480Y/277 V: FCAN 1-5% FCBN: 2-5%
Micron General Purpose Transformer, Group A, 250VA, Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 240x480, SEC: 120/240V
Micron General Purpose Transformer, Group N, 225 kVA Type 3-V, PRI: 600 V TO 208Y/120 V: FCAN: 2-2.5% FCBN: 4-2.5%
Micron General Purpose Transformer, Group M, 225 kVA Type 3-V, PRI: 480 V TO 480Y/277 V: FCAN: 2-2.5% FCBN: 4-2.5%
Micron General Purpose Transformer, Group L, 225 kVA Type 3-V, PRI: 480 V TO 240 V w/ 120 V lighting tap on B phase (center tap capacity limited to 5% of rated kVA) FCAN: 2-2.5% FCBN: 4-2.5 %
Micron General Purpose Transformer, Group J, 225 kVA Type 3-V, PRI: 480 V SEC: 208Y/120 V: FCAN: 2-2.5% FCBN: 4-2.5%
Micron General Purpose Transformer, Group I, 225 kVA Type 3-V, PRI: 240V SEC: 208Y/120 V: FCAN 1-5%: FCBN: 2-5% 240 V
Micron General Purpose Transformer, Group H, 225 kVA Type 3-V, Three-phase, Ventilated, 60Hz, PRI: 280 V SEC: 480Y/277 V: FCAN 1-5% FCBN: 2-5%
Micron General Purpose Transformer, Group E, 1.5 kVA Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 208 V; SEC: 120/240 V
Micron General Purpose Transformer, Group D, 1.5 kVA Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 600 V SEC: 120/240 V; FCBN: 2-5%
Micron General Purpose Transformer, Group B, 1.5 kVA, Type 1-E, Single-phase, Encapsulated, 50/60Hz (Export Model), PRI: 190/200/208/220/380/400/416/440 V SEC: 110/220 V 50/60 HZ
Micron General Purpose Transformer, Group A, 1500VA, Type 1-E, Single-phase, Encapsulated, 60Hz, PRI: 240x480, SEC: 120/240V
OVERVIEW
Low Voltage General Purpose transformers are used to change voltage and are suitable for a wide variety of applications and are in accordance with NEMA, ANSI, and IEEE standards as applicable. Models are available in encapsulated or ventilated types to fit a variety of environments
Micron Low Voltage General Purpose • Built and tested in accordance with applicable NEMA, ANSI and IEEE standards Encapsulated• Suitable for indoor or outdoor applications Ventilated• Primarily for indoor locations (Outdoor use with optional weathershields) |