RK1 A6D Time Delay

Compare To...

Bussman / EatonLPSCefCoLOSEatonLES-RLittelfuseLLS-RK
Bussman / EatonLPS-RCefCoLOS-REatonLES-RK  
Bussman / EatonLPS-RKSPCefCoLOS-RKEatonSCLR-S  
Bussman / EatonRKSEatonLESGould-ShawmutATS-DER   

56 Products

A6D300/600R

Ferraz Shawmut Class RK1 Time Delay Reducer fuse, 600V, 300 Ampere, 300kA IR, 600 Ampere body size,


Drop Ship
$746.30
QuantityPrice
A6D350R

Ferraz Shawmut Class RK1 Time Delay Fuse, 600VAC, 300kA IR, 350 Ampere,


Drop Ship
$262.75
QuantityPrice
A6D350/600R

Ferraz Shawmut Class RK1 Time Delay Reducer fuse, 600V, 350 Ampere, 300kA IR, 600 Ampere body size Non-cancelable


Drop Ship
$746.30
QuantityPrice
A6D400R

Ferraz Shawmut Class RK1 Time Delay Fuse, 600VAC, 300kA IR, 400 Ampere,


Drop Ship
$262.75
QuantityPrice
A6D400/600R

Ferraz Shawmut Class RK1 Time Delay Reducer fuse, 600V, 400 Ampere, 300kA IR, 600 Ampere body size,


Drop Ship
$746.30
QuantityPrice
A6D450R

Ferraz Shawmut Class RK1 Time Delay Fuse, 600VAC, 300kA IR, 450 Ampere,


Drop Ship
$381.40
QuantityPrice
A6D500R

Ferraz Shawmut Class RK1 Time Delay Fuse, 600VAC, 300kA IR, 500 Ampere,


Drop Ship
$381.40
QuantityPrice
A6D600R

Ferraz Shawmut Class RK1 Time Delay Fuse, 600VAC, 300kA IR, 600 Ampere,


Drop Ship
$381.40
QuantityPrice

 OVERVIEW


Specifications

• Time-delay for motor starting and transformer inrush currents without nuisance opening
• Volts: 600VAC/DC
• 200kA IR (AC), 100kA IR (DC)
• Solid state SmartSpot visual blown fuse indicator
• Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
• High-visibility orange label ensures instant recognition
• Reduced inventory by taking the place of Class RK5, K, and H fuses
• Fiberglass body provides dimensional stability in harsh industrial settings
• Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “black outs”
• Reducer fuses available as permanent solution to decrease current rating without replacing fuse holders



Approvals

• UL listed to standard 248-12 File E2137
• DC listed to UL standard 248
• CSA certified to standard C22.2 No. 248.12



Reducer Fuses

• Reducer fuses are a permanent solution to decrease current rating
• Reduced amp ratings designed to fit into larger fuse holders
• Lower the amp rating of the system without replacing fuse holders or fuse panel
• Ratings available from 110 to 400 Amperes


 Applications



Time delay fuses are the most useful fuses for motor branch circuit application. A time delay fuse can be sized closer to motor full load current, providing a degree of overload protection, better short circuit protection, and possible use of a smaller disconnect switch.

Some example applications include:
• Motors
• Safety Switches
• Transformers
• Branch Circuit Protection
• Disconnects
• Control Panels