XBL-DSEA, PLC Module, DeviceNet Server

XBL-DSEA, PLC Module, DeviceNet Server

**Limited to Stock on Hand** LS Electric XGB Communication Expansion Module, DeviceNet Server, Use with SU, M, and U Type PLCs. Expansion power requirement 100mA

Item: XBL-DSEA
(0) No Reviews yet
Weight: 0.25 lbs.
Made in: Korea (the Republic of)
$174.20
In Stock
SKU:XBL-DSEA

Orders up to 6PM ET Ship same day!

Specifications

**Limited to Stock on Hand** LS Electric XGB Communication Expansion Module, DeviceNet Server, Use with SU, M, and U Type PLCs. Expansion power requirement 100mA

  • Maximum Automation at Minimum Cost
  • Available Communication Expansion Modules: RS-422/485, RS-232C, Ethernet I/F, EtherNet I/P, Profibus-DP (Master/Slave), DeviceNet (Slave), CANopen (Master/Slave)
  • Snap-on Modules for Flexible Installation
  • Additional Capabilities for Complex Tasks
  • Agency ApprovaLS Electric: UL / cUL / CE
  • 2-year Warranty

GENERAL SPECIFICATIONS

Internal Current Consumption100mA
External Current Consumption100mA at 24VDC
Transmission Speed125/250/500kbps
Transmission TypePoll, Bit Strobe, COS, Cyclic
Communication DistanceThick Cable: 1640 feet (500m) 125kbps/ 820.2 feet (250m) 250kbps/
328.1 feet (100m) 500kbps

Thin Cable: 328.1 feet (100m) 125/250/500kbps
Terminal Resistance121Ω (1%,1/4W)
Maximum Extended Drop Length125kbps: 511.8 feet (156m)
250kbps: 255.91 feet (78m)
500kbps: 127.95 feet (39m)
Data Packet0 - 8 bytes
Message Access ControlCSMA/NBA
Network StructureTrunk/Drop Line, Power/Signal Cable Inside Network Cable
Bus TypePoll
Maximum Number of NodesUp to 64 (including Master) MAC Identifiers
System FeaturesInsertion/Removal of Node, Available in Voltage On Status
Diagnosis FunctionModule: Checks duplicated station / Checks CRC error

SyCon: Detects defective station / Checks bus off / Auto-scan function

XG5000: Monitors high-speed link
Data Process UnitWord
Send/Receive Period10/20/50/100/200/500ms, 1/5/10s (Default:20ms)
Maximum Communication PointSend: 2048 Points, 256bytes

Receive: 2048 Points, 256 bytes
Maximum Block Number64 (Setting Range: 0 - 63)
Maximum Point Number per Block2048 Points (256 bytes)

Application Notes

TitleSummaryRelated Links
AN-XGB-100

Introduction to the LS Electric XGB family of PLC’s.

Introduction to the LS Electric Systems XGB family of PLC’s and free XG5000 programming software...
AN-XGB-101

Introduction to the LS Electric XGB E Type PLC

Introduction to the LS Electric XGB E Type PLC...
AN-XGB-102

Introduction to the LS Electric XGB SU Type PLC

Introduction to the LS Electric XGB SU Type PLC...
AN-XGB-103

Introduction to the LS Electric XGB M Type PLC

Introduction to the LS Electric XGB M Type PLC...
AN-XGB-104

Introduction to the LS Electric XGB U Type PLC

Introduction to the LS Electric XGB U Type PLC...
AN-XGB-105

LS Electric XG5000 Programming software

Introduction to the LS Electric XG5000 PLC programming software
AN-XGB-106

Download and Install XG5000

Downloading and installing the free XGB XG5000 programming software…
AN-XGB-107

Build an XGB PLC Program

Building an XGB PLC program…
AN-XGB-108

Download an XGB Program

Downloading and Testing an XGB PLC program…
AN-XGB-109

E / SU Type - Quick Start Guide

The quick start guide is intended to show basic setup and programming...
AN-XGB-110

M Type - Quick Start Guide

The quick start guide is intended to show basic setup and programming...
AN-XGB-111

U Type - Quick Start Guide

The quick start guide is intended to show basic setup and programming...
AN-XGB-112

E and SU Type Discrete Memory Addressing

Explanation of the XGB E and SU Type PLC Discrete I/O Addressing…
AN-XGB-113

M Type Discrete Memory Addressing

Explanation of the XGB M Type PLC Discrete I/O Addressing…
AN-XGB-114

U Type Discrete Memory Addressing

Explanation of the XGB U Type PLC Discrete I/O Addressing…
AN-XGB-115

XGB E Type PLC Option Board Discrete Addressing

Explanation of the XGB E Type PLC Option Board Discrete I/O Addressing…
AN-XGB-116

XGB SU Type PLC Expansion I/O Discrete Addressing

Explanation of the XGB SU Type PLC Expansion Hardware Discrete I/O Addressing…
AN-XGB-117

XGB M Type PLC Expansion I/O Discrete Addressing

Explanation of the XGB M Type PLC Expansion Module I/O Addressing…
AN-XGB-118

XGB U Type PLC Expansion I/O Discrete Addressing

Explanation of the XGB U Type PLC Expansion Module I/O Addressing…
AN-XGB-119

Wiring the TG7-1H40S Terminal Board to XBM-DN32H

A diagram of how to wire the TG7-1H40S terminal board to the XBM-DN32H PLC using a smart link cable C40HH-xxSB-XBI.
AN-XGB-120

XGB PLC Discrete I/O Configuration

Configuring Discrete I/O Modules and Identifying the Discrete Addresses…
AN-XGB-121

XGB PLC Analog Input Module Configuration

Configuring and using Analog Input Modules…
AN-XGB-122

XGB PLC Thermocouple Module Configuration

Configuring and Using Thermocouple Modules…
AN-XGB-123

XGB PLC Analog Output Module Configuration

Configuring and using Analog Output Modules…
AN-XGB-124

XGB PLC Ethernet Module Setup

Configuring the Ethernet module for Modbus TCP…
AN-XGB-125

XGB PLC Ethernet Modbus Address Mapping

Mapping XGB PLC addresses to Modbus addresses…
AN-XGB-126

XGB PLC Thermocouple Module Ladder Example

Using the XGB thermocouple module in ladder logic…
AN-XGB-127

XGB PLC Analog Input Module Ladder Example

Using the XGB analog input module in ladder logic…
AN-XGB-128

XGB PLC Analog Output Module Ladder Example

Using the XGB analog output module in ladder logic…
AN-XGB-129

Wiring the XBM-DN32H for Positioning Control

A diagram of how to wire the XBM-DN32H PLC for positioning control...
AN-XGB-130

XGB PLC PID Functionality

Configuring and using the XGB PLC’s PID loop functionality…
AN-XGB-131

Assigning XGB PLC Addresses to Variables

Using XG5000 to assign variable names to PLC addresses…
AN-XGB-132

Configuring an XGB PLC and IMO HMI for XGB Dedicated Protocol

Using XG5000 and iView Developer to configure a connection between the PLC and HMI using XGB Dedicated Protocol…
AN-XGB-133

Configuring an XGB PLC and IMO HMI for Modbus RTU Protocol

Using XG5000 and iView Developer to configure a Modbus RTU connection between the PLC and HMI…
AN-XGB-134

Configuring an XGB PLC and IMO HMI for Modbus TCP Protocol

Using XG5000 and iView Developer to configure a Modbus TCP Ethernet connection between the PLC and HMI…

Ratings & Reviews

No reviews available

Be the first to Write a Review

Ratings & Reviews

No reviews available

Be the first to Write a Review