XBC-DR30SU, PLC, XBC SU-Type, 110/240VAC Power, 18 24VDC IN, 12 Relay OUT

LS Industrial XGB Series PLC, XBC Standard SU-Type Unit, 110/240VAC Input Power, 18 24VDC Inputs, 12 Relay Outputs, 2A/Point, 5A/COM, 5 COM, 2 Option slots, Expandable (Max. 254 pts) I/O, Expansion power provision 870mA
Item: XBC-DR30SU
(0) No Reviews yet
$198.00
SKU: XBC-DR30SU
$198.00
Orders up to 7PM ET Ship same day!
Weight: 1.164 lbs.
Made in: Korea, Republic of

Related Videos

Specifications

LS Industrial XGB Series PLC, XBC Standard SU-Type Unit, 110/240VAC Input Power, 18 24VDC Inputs, 12 Relay Outputs, 2A/Point, 5A/COM, 5 COM, 2 Option slots, Expandable (Max. 254 pts) I/O, Expansion power provision 870mA
  • Flexible Connectivity using up to 7 Expansion Modules
  • 2 Option Modules capability for Expansion
  • 2 Programming Ports (Mini-DIN & USB Mini-B)
  • 2 Peripheral Ports (RS232 & RS485)
  • Powerful Performance, Fast Processing Speed (0.09µs/step)
  • Built-in Functions: RS-232C/485 (2-ch), High-Speed Counter, PID Control, Pulse Catch, Input Filter, External Interrupt, Positioning
  • Agency Approvals: UL / cUL / CE
  • 2-year Warranty

General Specifications

Input
Rated Voltage (UL warranty voltage)AC 100 ∽ 240 V
Input voltage rangeAC85∽ 264V(-15%, +10%)
Inrush current50APeak or less
Input current0.5A or less (220V), 1A or less (110V)
Efficiency65%
Permitted momentary power failure10ms or less
Power supply status indicationLED On when power supply is normal
Rated Output1.5A @ DC5V; 0.3A @ DC24V
Voltage RippleDC5V (±2%)
Cable specification0.75 ∽ 2 mm2
Digital input0.18 (AWG24) - 1.5 (AWG16)
Digital output0.18 (AWG24) - 2.0 (AWG14)
Analogue I/O0.18 (AWG24) - 1.5 (AWG16)
Communication0.18 (AWG24) - 1.5 (AWG16)
Main power1.5 (AWG16) - 2.5 (AWG12)
Protective grounding1.5 (AWG16) - 2.5 (AWG12)
Terminal Strip Torque3.7 - 5.1 in/lb
Dimnesions in. (LxHxD)5.3 x 3.5 x 2.5"

I/O Specifications

DC Inputs
Operation Voltage Range20.4–28.8VDC (Within Ripple Rate 5% )
Rated Input Voltage24VDC
Rated Input Current4mA (Contact Point 0–1: 16mA, 2–7: 10mA)
Input Resistance5.6kΩ (P00–P07: 2.7kΩ )
On Voltage/On Current19VDC or Higher/3mA or Higher
Off Voltage/Off Current6VDC or Less/1mA or Less
Response Time
Off ➔ On / On ➔ Off1/3/5/10/20/70/100ms (Set by CPU Parameter) Default: 3ms
Insulation Voltage560VAC rms/3 Cycle (Altitude 2000m)
Insulation Resistance10MΩ or Higher
Relay Outputs
Rated Load Voltage/Current24VDC 2A/220VAC 2A, 5A/COM
Min. Load Voltage/Current5VDC/1mA
Max. Load Voltage250VAC, 125VDC
Off Leakage Current0.1mA (220VAC, 60Hz)
Max. On/Off Frequency3,600 Times/Hour
Response Time
Off ➔ On10ms or Less
On➔ Off12ms or Less
Service Life
MechanicalRated Load Voltage/Current 100,000 Times or More
Electrical200VAC/1.5A, 240VAC/1A 100,000 Times or More
200VAC/1A, 240VAC/0.5A 100,000 Times or More
24VDC/1A, 100VDC/0.1A 100,000 Times or More

Communication Specifications

Performance Specifications
Program Control MethodFixed Scan Time, Constant Scan
I/O Control MethodScan Synchronous Batch Processing Method (Refresh Method), Directed by Program Instruction
Program LanguageLadder Diagram, Instruction List
Processing Speed94µs /1K boolean
Program Capacity15k steps
Expansion CapabilityExpansion Modules and Option Boards (Max. 7 Combined)
Data Area
PP0000–P1023F (16,384 point)
MM0000–M1023F (16,384 point)
KK00000–K4095F (65,536 point)
LL00000–L2047F (32,768 point)
FF000–F1023F (16,384 point)
T100ms, 10ms, 1ms: T0000–T255 T1023 (1,024 point)(Adjustable by Parameter Setting)
CC000–C1023 (1,024)
SS00.00–S127.99
DD0000–D10239 (10,240 word)
UU00.00–U0A.31 (Analog Data Refresh Area: 352 word)
ZZ000–Z127 (128 word)
RR0000–R10239 (10,240 word)
Total Programs128
Tasks Available
Initial Task1
Cyclic Task8
I/O Task8
Internal Device Task8
Operation ModeRun, Stop, Debug
Self-Diagnosis FunctionDetects Errors of Scan Time, Memory, I/O
Program PortsMini DIN 6-Pin RS-232C, USB 1 Channel
Back-up MethodLatch Area Setting in Basic Parameter
Built-in Functions
PID ControlControl by Instruction, Auto-Tuning, PWM Output, Manual Mode, Adjustable Operation Scan Time Setting, Anti-Windup, Delta MV, SV-Ramp Function, Max. 16 Loops
Serial
ProtocolDedicated Protocol, Modbus Protocol, User Defined Protocol
ChannelRS-232C 1 port, RS-485 1 port
High Speed Counter
Performance1 Phase: 100kHz, 2 Channel/20kHz, 6 Channel 2 Phase: 50kHz, 1 Channel/8kHz, 3 Channel
Counter ModeBased on Input Pulse and INC/DEC method – 1 Phase Pulse Input: Addition/Subtraction Counter 2 Phase Pulse Input: Addition/Subtraction Counter 2 Phase Pulse Input: Addition/Subtraction by Pulse Phase Change?(Encoder)
FunctionInternal/External Preset, Latch Counter, Compare Output, No. of Rotation per Unit Time
Positioning
Control Axis/Method2 Axis, Position/Speed Control
ControlPulse, Positioning Data: 80 Data/Axis (Operation Step No. 1–80)
OperationEnd/Keep/Continuous, Single, Repeated Operation
Positioning MethodAbsolute/Incremental, Address Range: – 2,147,483,648 to 2,147,483,647
SpeedMax. 100kpps (Setting Range 1–100,000pps)
Acceleration/DecelerationTrapezoidal Method
Additional FunctionsInching Operation, Speed Synchronizing, Position Synchronizing, Linear Interpolation
Pulse Catch10µs 2 point (P0000–P0001), 50µs 6 point (P0002–P0007)
Input Filtering Time Setting Range1, 3, 5, 10, 20, 70, 100ms
External Interrupt10?: 2 Points (P00000–P00001)
50µs : 6 Points (P00002–P00007)
RTCOption Board Required

Related Items

Knowledge base

TitleSummaryRelated Links
AN-XGB-100

Introduction to the LS IS XGB family of PLC’s.

Introduction to the LS Industrial Systems XGB family of PLC’s and free XG5000 programming software...
AN-XGB-101

Introduction to the LS XGB E Type PLC

Introduction to the LS XGB E Type PLC...
AN-XGB-102

Introduction to the LS XGB SU Type PLC

Introduction to the LS XGB SU Type PLC...
AN-XGB-103

Introduction to the LS XGB M Type PLC

Introduction to the LS XGB M Type PLC...
AN-XGB-104

Introduction to the LS XGB U Type PLC

Introduction to the LS XGB U Type PLC...
AN-XGB-105

LS XG5000 Programming software

Introduction to the LS XG5000 PLC programming software
AN-XGB-106

Download and Install XG5000

Downloading and installing the free XGB XG5000 programming software…
AN-XGB-107

Build an XGB PLC Program

Building an XGB PLC program…
AN-XGB-108

Download an XGB Program

Downloading and Testing an XGB PLC program…
AN-XGB-109

E / SU Type - Quick Start Guide

The quick start guide is intended to show basic setup and programming...
AN-XGB-110

M Type - Quick Start Guide

The quick start guide is intended to show basic setup and programming...
AN-XGB-111

U Type - Quick Start Guide

The quick start guide is intended to show basic setup and programming...
AN-XGB-112

E and SU Type Discrete Memory Addressing

Explanation of the XGB E and SU Type PLC Discrete I/O Addressing…
AN-XGB-113

M Type Discrete Memory Addressing

Explanation of the XGB M Type PLC Discrete I/O Addressing…
AN-XGB-114

U Type Discrete Memory Addressing

Explanation of the XGB U Type PLC Discrete I/O Addressing…
AN-XGB-115

XGB E Type PLC Option Board Discrete Addressing

Explanation of the XGB E Type PLC Option Board Discrete I/O Addressing…
AN-XGB-116

XGB SU Type PLC Expansion I/O Discrete Addressing

Explanation of the XGB SU Type PLC Expansion Hardware Discrete I/O Addressing…
AN-XGB-117

XGB M Type PLC Expansion I/O Discrete Addressing

Explanation of the XGB M Type PLC Expansion Module I/O Addressing…
AN-XGB-118

XGB U Type PLC Expansion I/O Discrete Addressing

Explanation of the XGB U Type PLC Expansion Module I/O Addressing…
AN-XGB-119

Wiring the TG7-1H40S Terminal Board to XBM-DN32H

A diagram of how to wire the TG7-1H40S terminal board to the XBM-DN32H PLC using a smart link cable C40HH-xxSB-XBI.
AN-XGB-120

XGB PLC Discrete I/O Configuration

Configuring Discrete I/O Modules and Identifying the Discrete Addresses…
AN-XGB-121

XGB PLC Analog Input Module Configuration

Configuring and using Analog Input Modules…
AN-XGB-122

XGB PLC Thermocouple Module Configuration

Configuring and Using Thermocouple Modules…
AN-XGB-123

XGB PLC Analog Output Module Configuration

Configuring and using Analog Output Modules…
AN-XGB-124

XGB PLC Ethernet Module Setup

Configuring the Ethernet module for Modbus TCP…
AN-XGB-125

XGB PLC Ethernet Modbus Address Mapping

Mapping XGB PLC addresses to Modbus addresses…
AN-XGB-126

XGB PLC Thermocouple Module Ladder Example

Using the XGB thermocouple module in ladder logic…
AN-XGB-127

XGB PLC Analog Input Module Ladder Example

Using the XGB analog input module in ladder logic…
AN-XGB-128

XGB PLC Analog Output Module Ladder Example

Using the XGB analog output module in ladder logic…
AN-XGB-129

Wiring the XBM-DN32H for Positioning Control

A diagram of how to wire the XBM-DN32H PLC for positioning control...
AN-XGB-130

XGB PLC PID Functionality

Configuring and using the XGB PLC’s PID loop functionality…
AN-XGB-131

Assigning XGB PLC Addresses to Variables

Using XG5000 to assign variable names to PLC addresses…
AN-XGB-132

Configuring an XGB PLC and IMO HMI for XGB Dedicated Protocol

Using XG5000 and iView Developer to configure a connection between the PLC and HMI using XGB Dedicated Protocol…
AN-XGB-133

Configuring an XGB PLC and IMO HMI for Modbus RTU Protocol

Using XG5000 and iView Developer to configure a Modbus RTU connection between the PLC and HMI…
AN-XGB-134

Configuring an XGB PLC and IMO HMI for Modbus TCP Protocol

Using XG5000 and iView Developer to configure a Modbus TCP Ethernet connection between the PLC and HMI…

Ratings & Reviews

No reviews available

Be the first to Write a Review