00158ET3W90L-W22, 3 PH IEC Tru-Metric - TEFC 2 HP, 1800/1500 RPM, 1.5 kW, 90L NEMA, Footed, 460//220-240/380-415V
00158ET3W90L-W22, 3 PH IEC Tru-Metric - TEFC 2 HP, 1800/1500 RPM, 1.5 kW, 90L NEMA, Footed, 460//220-240/380-415V
WEG Three-Phase W22 IEC Tru-Metric - TEFC (IP55) Cast Iron Frame, 2 HP, 1800/1500 RPM, 1.5 kW, 90L NEMA Frame, Footed, 1.25 Service Factor, 460//220-240/380-415V. Can be fitted with C-Flange kit FLC-IM90DIN-AL-UBC, or D-Flange kit FLF-IM90-AL-UBC
*Images are for illustrative purposes and may not represent the actual configuration of the product.
Specifications
WEG Three-Phase W22 IEC Tru-Metric - TEFC (IP55) Cast Iron Frame, 2 HP, 1800/1500 RPM, 1.5 kW, 90L NEMA Frame, Footed, 1.25 Service Factor, 460//220-240/380-415V. Can be fitted with C-Flange kit FLC-IM90DIN-AL-UBC, or D-Flange kit FLF-IM90-AL-UBC
*Images are for illustrative purposes and may not represent the actual configuration of the product.
- Premium efficiency - complying with IE3 efficiency levels according to IEC60034-30;
- Output: 0,12 up to 500kW;
- Number of Poles: 2, 4, 6 or 8;
- Frames: 63 up to 355M/L;
- Mounting: F-2 / B3L(E);
- Frequency: 60//50 Hz;
- Voltage: 460//220-240/380-415V with 6 cables for frames 63 to 100L and 460//380-415V with 6 cables for frames 112M to 355M/L;
- Class “F” insulation (?T=80K);
- Continuous duty: S1;
- Design N;
- Ambient temperature: 40°C, at 1000 m.a.s.l.;
- Squirrel cage rotor / Aluminium die cast;
- V'Ring seal for frames 63 to 200L and WSeal® for frames 225S/M to 355M/L;
- Stainless steel nameplate AISI 316;
- Fan Covers: steel made for frames 63 to 132M/L and cast iron made for frames 160M to 355A/B;
- Regreasing nipple for frames 160M to 355M/L;
- Metric threaded cable entries on the terminal box;
- Color: RAL 5009 - Blue.
Specifications
| Phase | Three Phase |
| Frame | 90L |
| Output | 2 HP |
| Poles | 04 |
| Frequency | 60 Hz |
| Rated speed | 1755 rpm |
| Slip | 2.50 % |
| Full Voltage - No Cables | 460//220-240/380-415 V |
| Rated Current | 2.83 A |
| LR Amperes | 23.5 A |
| LRC | - |
| No Load Current | 1.68 A |
| Rated Torque | 5.98 ft.lb |
| Locked Rotor Torque | 310 % |
| Breakdown Torque | 390 % |
| Insulation Class | F |
| Service Factor | 1.25 |
| Moment of Inertia | 0.1566 sq.ft.lb |
| Design | N |
| Locked Rotor Time | 25s (cold) 14s (hot) |
| Temperature Rise | 80 K |
| Duty Cycle | S1 |
| Maximum Room Temperature | 40 °C |
| Minimum Room Temperature | -20 °C |
| Degree of Protection | IP55 |
| Altitude | 1000 m |
| Cooling Method | TEFC Totally Enclosed Fan Cooled |
| Mounting | F-2 |
| Rotation Direction | Both |
| Noise Level | 49.0 dB(A) |
| Starting Method | - |
| Enclosure Material | Iron |
| Front Bearing Shielding | ZZ |
| Front Bearing Size | 6205 |
| Front Bearing Type | Ball |
| Front Sealing Type | V Ring |
| Rear Bearing Shielding | ZZ |
| Rear Bearing Size | 6204 |
| Rear Bearing Type | Ball |
| Rear Sealing Type | No Rear Sealing |
| Grease Type | Mobil Polyrex EM |
| VFD Turndown VT | 1000:1 |
| VFD Turndown CT | 12:1 |
Application Notes
| Title | Summary | Related Links |
|---|---|---|
| AN-GEN-004 Determining Motor Full Load Amps (FLA) | How to determine your motor’s FLA. |